Key takeaways
- Almost every gas boiler needs electricity, so a power cut means no heating; tell callers to report outages on 105[1].
- Network operators must restore power within 12 hours in normal weather, 24 hours in category 1 storms and 48 hours in category 2 storms[1].
- After power returns, a short reset checklist clears most calls without a visit.
- Generators, gas cookers and barbecues used for heat indoors are a carbon monoxide risk[2]; check every customer has a working CO alarm.
- Storm-damaged flues and terminals need an engineer before the boiler is used again.
Why a storm fills a heating firm's phone
When a storm brings down power lines, gas central heating stops too. At the 2021 Census, mains gas was the central heating fuel for 73.8% of households in England and Wales[3], and almost every modern gas boiler relies on electricity for its fan, pump, ignition and controls. Electric central heating, used by another 8.5% of households at the same census[4], stops for the obvious reason. The calls come in two waves: during the outage, from people asking what to do, and after it, from people whose heating has not come back on.
Most of these calls do not need a visit. They need a clear answer, a safe reset routine and an engineer for the few that are real faults or safety problems. Prepare the answers before the storm season so whoever answers the phone can give them.
How long power cuts should last
Customers want to know how long they will be without heat. Ofgem sets the standards: power should be restored within 12 hours for interruptions outside severe weather, within 24 hours in category 1 severe storms and within 48 hours in category 2 storms[1]. Power cuts can be reported free by calling 105, which connects to the local network operator.
Source: Ofgem, 2026[1]
Show the data
| Conditions | Value |
|---|---|
| Normal weather | 12 hours |
| Category 1 severe storm | 24 hours |
| Category 2 severe storm | 48 hours |
Customers may also be due compensation. For 2026, Ofgem lists a payment of £100 for homes when a cut affecting fewer than 5,000 properties lasts more than 12 hours, with further payments for each extra 12 hours, and separate amounts for larger cuts and severe weather[1]. Payments are usually automatic. Mentioning this calmly helps customers who are anxious and cold.
Phone script during a power cut
- Ask: is the power off in the whole house, and are neighbours affected? If yes, the boiler has stopped because of the outage, not a fault.
- Tell them to report it by calling 105 if they have not already.
- Advise them not to keep pressing the boiler reset during the outage; it will not help.
- Give safe ways to stay warm: one room, warm layers, hot drinks, curtains closed, and never a gas cooker, camping stove, barbecue or outdoor heater used indoors for heat.
- Explain the reset steps for when power returns (below), and that they should call back if the boiler still will not run.
- If anyone at home is at higher risk from cold, note it and ask the network operator about extra help for vulnerable customers.
When the power comes back: reset checklist
Wait a few minutes
Supply can flicker on and off as the network is restored. Give it a few minutes before doing anything.
Check the programmer and thermostat
Many lose the time or settings in an outage. Reset the clock and the heating schedule. Smart thermostats may need to reconnect to the internet.
Check boiler pressure
If the gauge is below the level in the manual, top up with the filling loop only if the customer knows how.
Reset once
If the boiler shows a lockout, press reset once as the manual describes. If it locks out again, stop and call an engineer.
Check the condensate pipe in frost
If temperatures fell during the outage, the outside condensate pipe may have frozen. Thaw with warm (not boiling) water.
Give heat pumps time
Heat pumps can take longer to restart and may run a defrost cycle first. Check the controller for error codes before calling.
Frost protection in a long outage
A boiler's frost protection only works with power. In a long outage in freezing weather, pipes in lofts, garages and outside walls are at risk. If power is not expected back for a day or more and temperatures are below freezing, advise customers to turn off the water at the stop tap and open a cold tap to drain the pipes they can, especially if they are leaving the home. In a home that will stay empty, a proper drain-down by an engineer may be safer.
Tell customers who leave to stay elsewhere to leave a note of what they turned off, so the restart is straightforward and nobody turns the water on to a split pipe.
Generators, temporary heat and carbon monoxide
Power cuts bring a spike in unsafe heating. The NHS lists gas boilers, gas cookers and gas or paraffin heaters among household appliances that can produce carbon monoxide when badly installed, faulty or poorly maintained[2]. Portable generators, barbecues and camping stoves produce it too. Anyone who suspects carbon monoxide poisoning should stop using the appliance and get medical advice[5].
- Generators must run outdoors, away from doors, windows and vents. Never in a garage or porch.
- Never use a gas cooker or oven to heat a room.
- Do not bring outdoor heaters, barbecues or camping stoves indoors.
- Check the customer has a working carbon monoxide alarm; only 62% of homes in England had one in 2024[6].
- Battery alarms keep working in a power cut; mains-wired alarms need a working backup battery.
If someone smells gas or suspects carbon monoxide, the advice is to leave the property, avoid switching electrics on or off, and call the National Gas Emergency Service on 0800 111 999[7]. When told of a gas escape, the gas conveyor (the network company) must attend as soon as reasonably practicable and stop the escape within 12 hours[8].
Storm damage to flues and terminals
High winds can bend or dislodge flue terminals, damage plume kits and blow debris into terminals and air inlets. Snow drifts can block low-level flues. A boiler with a damaged or blocked flue can spill combustion products into the home.
| Sign | Risk | Advice |
|---|---|---|
| Flue terminal bent, loose or missing | Combustion products may enter the home | Do not use the boiler; book an engineer |
| Plume kit or flue extension detached | Products discharged near windows or doors | Do not use the boiler; book an engineer |
| Leaves, debris or snow over a low-level terminal | Poor combustion, lockouts | Clear only if safe and reachable without tools; call if the boiler still locks out |
| Water coming through ceiling near a flue | Flue joint or roof damage | Turn off the boiler and electrics nearby if safe; book an engineer |
| Boiler roaring, yellow flames or soot marks | Combustion fault | Stop using it; ventilate; call the gas emergency number if CO is suspected |
Customers who rely on heat and power
For some customers a long power cut is more than an inconvenience: people who use electrically powered medical equipment, older people living alone, families with very young children. Network operators keep records of customers who need extra help in an outage, and encouraging vulnerable customers to register with their supplier or network operator before storm season is a small kindness that costs you nothing.
In your own records, flag customers who have told you they are at higher risk from cold, with their agreement. When a storm is forecast, a short call or text to those customers with the reset steps and the numbers to ring is often appreciated more than any marketing message. After the outage, ring them first to check their heating has come back.
Example: a storm weekend
Example (fictional): a three-engineer firm in Pembrokeshire takes 41 calls over a storm weekend. Twenty-six come during a 14-hour power cut and are handled with the phone script, including advice to report on 105. Eleven come after power returns: seven are cleared with the reset checklist, two are frozen condensate pipes thawed by the customer on the phone, and two need visits. One visit finds a flue terminal bent by the wind; the engineer makes the boiler safe and orders a replacement. The other is a customer running a generator in the garage; the engineer explains the risk, moves it outside and tests the CO alarm.
Prepare before storm season
- Put the power-cut script and reset checklist where everyone who answers the phone can see them.
- Add a storm message to your voicemail and website that gives 105 and the gas emergency number.
- Carry spare flue terminal guards and common plume kit parts for the boilers you fit most.
- Remind customers in autumn to check their carbon monoxide alarm batteries.
For empty homes in storm season, see winterising empty properties. If storms bring floodwater, read after a flood: plumbing and heating recovery work. For the phone questions on no-heat calls, use triage questions for no-heating calls.
Frequently asked questions
Why does my gas boiler not work in a power cut?
Modern gas boilers need electricity for the fan, pump, ignition and controls. When power returns, check the programmer, the pressure and reset once if needed.
Who do customers call about a power cut?
They can call 105 free to report it to the local network operator[1].
Is it safe to run a generator to power the boiler?
Only if it is outdoors, well away from doors, windows and vents, and connected safely. Generators produce carbon monoxide and must never run inside a home or garage.
What should a customer do if the flue was damaged in the storm?
Stop using the boiler and book a Gas Safe registered engineer. If they suspect carbon monoxide, they should leave the property and call 0800 111 999[7].
References
Ofgem (2026). Check if you can get a payment for a power cut (opens in a new tab) ↑
NHS (2026). Carbon monoxide poisoning (opens in a new tab) ↑
Office for National Statistics (2021). Housing, England and Wales: Census 2021 (opens in a new tab) ↑
Office for National Statistics (2021). Housing, England and Wales: Census 2021 (opens in a new tab) ↑
NHS (2026). Carbon monoxide poisoning (opens in a new tab) ↑
Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Housing Survey 2024 to 2025: Chapter 1, housing quality (opens in a new tab) ↑
National Gas (2026). Emergency contacts (opens in a new tab) ↑
legislation.gov.uk (The National Archives) (1996). The Gas Safety (Management) Regulations 1996, regulation 7 (opens in a new tab) ↑