Regulation compliance

Boiler wiring and Part P: what heating engineers may do

Which boiler and controls wiring is notifiable under Part P in England, the special location rules for bathrooms, and how to certify the work.

Ava research teamPublished 7 min read

On this page
  1. The question heating engineers actually ask
  2. What Part P requires of all electrical work
  3. The three notifiable categories in England
  4. Boilers and controls near baths and showers
  5. Heat pumps change the picture
  6. Routes to compliance for notifiable work
  7. Testing and paperwork for non-notifiable work
  8. Example: a boiler move in a terraced house
  9. Wales and the rest of the UK
  10. Frequently asked questions
  11. References

Key takeaways

  • In England, electrical work is notifiable if it is a new circuit, a consumer unit replacement, or an addition or alteration to circuits in a special location[1].
  • A special location includes the zone around a bath or shower up to 2.25 metres high and 0.6 metres from the bath or tray edge[1].
  • All electrical work in dwellings must still be designed and installed to protect people from fire or injury, notifiable or not[2].
  • Condensing combination boilers were in 63% of English homes in 2024[3], so boiler and controls wiring is everyday work.

The question heating engineers actually ask

Every heating engineer wires boilers, programmers, room thermostats and zone valves. The recurring question is not whether you can do electrical work at all, but when that work has to be notified to building control and when it can simply be done well, tested and recorded. Getting it wrong either way causes problems: notifying everything wastes time and money, while missing notifiable work leaves the customer without the paperwork they need when they sell.

The answer depends on three things: what the work is, where it is, and which nation the property is in. This guide covers England, where the rules are clearest, and flags where Wales differs.

Boiler wiring is everyday work because boilers are everywhere. In England, 63% of homes had a condensing combination boiler in 2024 and a further 19% another condensing boiler, up from 2% and 1% in 2001[3]. Almost all of those boilers have a fused connection, a set of controls and, in older systems, a wiring centre and motorised valves.

Homes in England by boiler type, 2001 and 2024
Homes in England by boiler type, 2001 and 2024Column chart. Condensing combination boiler: 2001 2%, 2024 63%; Other condensing boiler: 2001 1%, 2024 19%.0%20%40%60%80%Condensing combination boiler · 2001: 2%2%Condensing combination boiler · 2024: 63%63%Condensing combination boilerOther condensing boiler · 2001: 1%1%Other condensing boiler · 2024: 19%19%Other condensing boilerHomes in England by boiler type, 2001 and 2024Column chart. Condensing combination boiler: 2001 2%, 2024 63%; Other condensing boiler: 2001 1%, 2024 19%.Condensing combination boilerCondensing combination boiler · 2001: 2%2%Condensing combination boiler · 2024: 63%63%Other condensing boilerOther condensing boiler · 2001: 1%1%Other condensing boiler · 2024: 19%19%
  • 2001
  • 2024

Source: Ministry of Housing, Communities and Local Government (GOV.UK), 2024[3]

Show the data
Item20012024
Condensing combination boiler2%63%
Other condensing boiler1%19%

What Part P requires of all electrical work

Part P of Schedule 1 to the Building Regulations has one requirement, P1: reasonable provision must be made in the design and installation of electrical installations to protect people operating, maintaining or altering them from fire or injury[2]. It applies to low and extra-low voltage installations in or attached to a dwelling, in the common parts of buildings serving dwellings, and in some outbuildings and gardens supplied from a dwelling[2].

Note what that means. Part P applies to all electrical work in a home, including the boiler connection you replaced this morning. Notification is a separate question about how compliance is checked. Non-notifiable work still has to meet P1, which in practice means working to the current edition of BS 7671, testing your work and recording the results.

The three notifiable categories in England

Regulation 12(6A) lists the electrical work that needs a building notice or full plans application, unless a registered competent person does it. The work is notifiable where it consists of the installation of a new circuit, the replacement of a consumer unit, or any addition or alteration to existing circuits in a special location[1].

How common heating electrical jobs fit the England notification rules in regulation 12(6A).
Notifiable categoryTypical heating exampleUsually notifiable?
New circuitA dedicated radial circuit from the consumer unit for a heat pump, immersion heater or electric boilerYes
Consumer unit replacementChanging the consumer unit to add capacity for a heat pumpYes
Addition or alteration in a special locationMoving a boiler or adding a fused spur within the bath or shower zoneYes
Alteration outside a special locationReplacing a boiler's fused spur, adding a room thermostat or wiring a new programmer on the existing supplyNo, but must comply and be tested
Like-for-like replacementReplacing a faulty zone valve or wiring centre on the same circuitNo, but must comply and be tested

Boilers and controls near baths and showers

The special location is defined precisely. Within a room containing a bath or shower, it is the space surrounding the bath tap or shower head that extends vertically from the finished floor to 2.25 metres, or to the shower head if that is fixed higher, and horizontally to 0.6 metres from the edge of the bath tub or shower tray, or 1.2 metres from the centre of the shower head where there is no tray[1]. A room containing a swimming pool or sauna heater is also a special location[1].

Boilers in bathrooms are common in older flats and small houses, often in an airing cupboard or on the wall beside the bath. If you add or alter any part of a circuit inside that zone, including a new spur, a relocated isolator or new controls wiring, the work becomes notifiable. Measure before you quote, and photograph the measurements.

  • Measure the 0.6 metre zone from the edge of the bath or tray, and the 2.25 metre height from the finished floor.
  • For walk-in showers without a tray, measure 1.2 metres from the centre point of the shower head.
  • Check whether the boiler's isolator or controls sit inside the zone, not just the boiler.
  • If you move the boiler out of the zone, the alteration to the circuit inside the zone may itself be notifiable.

Heat pumps change the picture

Gas boiler swaps rarely involve new circuits. Heat pumps usually do. An air source heat pump normally needs its own supply from the consumer unit, often with a new outdoor isolator, and the cylinder may need a new immersion circuit. Each new circuit is notifiable[1]. If the existing consumer unit has no spare capacity, its replacement is notifiable too[1].

Firms moving into heat pumps therefore face a choice: register with an electrical competent person scheme so their own electricians can self-certify, or work with a registered electrician who handles the electrical side. GOV.UK lists electrical installations among the work types that competent person schemes cover[4]. Either route works; what does not work is a heating engineer adding a new circuit without notification.

Routes to compliance for notifiable work

  1. Register with an electrical competent person scheme and self-certify the work, with the scheme notifying building control.
  2. Use a registered electrician for the notifiable part of the job, and coordinate their visit with yours.
  3. Give building control a building notice or full plans application before the work starts, and arrange inspection.

For most heating firms the second route is the most practical until electrical work becomes a regular part of their jobs. Agree in writing who is responsible for which parts, who tests what, and who issues which certificate. Make sure the customer receives every certificate, gas and electrical, in one handover pack, because a solicitor will ask for both when the house is sold.

Testing and paperwork for non-notifiable work

  1. Isolate and prove dead

    Isolate at the consumer unit or fused spur, lock off and prove dead with an approved voltage indicator before touching any conductor.

  2. Check the existing supply

    Confirm the circuit protecting the boiler is suitable, the fused spur is the correct rating for the appliance, and there is suitable earthing and bonding.

  3. Wire to instructions

    Follow the boiler and controls manufacturers' wiring diagrams, and label any changes in the wiring centre.

  4. Test

    Carry out the tests your work requires, such as continuity of protective conductors, insulation resistance and polarity, and check the controls operate correctly.

  5. Record

    Issue an appropriate certificate for minor electrical works, and leave the customer a copy with the boiler paperwork.

Only carry out electrical work you are trained and competent to do. Gas Safe registration is the legal requirement for gas work[5]; it is not an electrical qualification, and customers sometimes assume it is.

Example: a boiler move in a terraced house

Example: a customer in Bristol wants their combination boiler moved from the kitchen to a cupboard in the bathroom, next to the bath. The heating engineer measures and finds the new position sits 0.4 metres from the bath edge, inside the special location. Extending the boiler's circuit into that zone is notifiable, and installing or replacing a heating system can need building regulations approval in its own right[6].

The firm offers two options: keep the boiler in the bathroom and bring in a registered electrician to extend and certify the circuit, or move it to the landing cupboard, outside the zone, where the firm can extend the existing circuit itself and test it. The customer chooses the landing cupboard. The engineer registers the gas work through Gas Safe, issues a minor works certificate for the electrical extension, and notes the zone measurements on the job sheet.

Wales and the rest of the UK

The three-item list above is the England version of regulation 12. The Welsh version of the regulation does not contain paragraph (6A)[1], and Wales applies its own definition of notifiable electrical work. Scotland and Northern Ireland have separate building standards systems altogether. If you work across a border, check the rules for the property's location before deciding whether to notify.

When in doubt, measure, photograph and ask. A two-minute call to your scheme helpline costs far less than a missing certificate when the house is sold.

Frequently asked questions

Can a heating engineer replace a fused spur for a boiler?

Replacing a boiler's fused spur on the existing circuit outside a special location is not notifiable in England, but it must comply with Part P, be tested and be recorded.

Is a new circuit for a heat pump notifiable?

Yes. In England, installing a new circuit is notifiable, so it must be done by a registered competent person or notified to building control before work starts.

What is a special location in a bathroom?

The space around a bath tap or shower head up to 2.25 metres high and 0.6 metres from the bath or tray edge, or 1.2 metres from the shower head where there is no tray.

Does Gas Safe registration cover boiler wiring?

Gas Safe registration is the legal requirement for gas work. Electrical work on the boiler supply must still meet Part P, and the person doing it must be competent in electrical work.

References

  1. legislation.gov.uk (The National Archives) (2010). The Building Regulations 2010, regulation 12 (opens in a new tab) ↑

  2. legislation.gov.uk (The National Archives) (2010). The Building Regulations 2010, Schedule 1, Part P (opens in a new tab) ↑

  3. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Housing Survey 2024 to 2025: Chapter 2, energy efficiency (opens in a new tab) ↑

  4. GOV.UK (2026). Competent person scheme: current schemes and how schemes are authorised (opens in a new tab) ↑

  5. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 3 (opens in a new tab) ↑

  6. GOV.UK (2026). Building regulations approval (opens in a new tab) ↑