Landlord commercial work

Landlord compliance bundles: gas, legionella, CO alarms

How to package landlord safety checks you are competent to do, coordinate the rest, report clearly and avoid promising compliance you cannot deliver.

Ava research teamPublished 6 min read

On this page
  1. Why landlords buy bundles
  2. What you can do and what you coordinate
  3. Carbon monoxide alarms
  4. Legionella: practical control, not certificates
  5. Coordinating the rest
  6. What the gas safety part should cover
  7. Getting the scheduling right
  8. Building the bundle
  9. Worked Example: a ten-property landlord
  10. Words to avoid
  11. Frequently asked questions
  12. References

Key takeaways

  • Build bundles around what you are registered and competent to do: gas safety checks, boiler servicing, carbon monoxide alarm tests and simple water hygiene measures.
  • Gas appliances in rented homes must be checked at least every 12 months, and tenants must get the record within 28 days[1].
  • In England, a carbon monoxide alarm is required in any room with a fixed combustion appliance other than a gas cooker[2], yet only 62% of dwellings had one in 2024[3].
  • Never sell a legionella certificate: HSE says the law does not require one[4]. Sell practical control measures and clear records instead.
  • Coordinate electrical inspections and other checks through qualified partners, and say clearly on the report who did what.

Why landlords buy bundles

Landlords face a list of safety duties with different intervals, different rules and different trades. A gas check every year, alarms checked at the start of each tenancy, electrics every five years, a legionella risk assessment kept under review. Most would rather pay one firm to organise the lot than chase four. A compliance bundle turns that list into one booking, one visit where possible and one report.

For a heating firm, bundles create predictable, recurring work that fills the diary outside the winter peak, and they bring you into rented homes regularly, which is where repair and replacement work comes from. The risk is overreaching: putting checks in the bundle you are not competent to do, or using words like fully compliant that you cannot stand behind.

What you can do and what you coordinate

Example split of landlord safety checks for a plumbing and heating firm.
CheckThe rule (England)Who can do itIn your bundle?
Gas safety checkEach appliance and flue at intervals of not more than 12 months; record to tenants within 28 daysGas Safe registered engineerYes, the core of the bundle
Boiler serviceNot a legal requirement for landlords, but often required by manufacturers' warrantiesGas Safe registered engineerYes, alongside the check
Carbon monoxide alarmsRequired in rooms with a fixed combustion appliance other than a gas cooker; checked on the first day of each tenancy; repaired once reportedLandlord or anyone competent to test and fitYes: test, replace battery units, report
Smoke alarmsOne on each storey used as living accommodation; checked on the first day of each tenancyLandlord or competent person; mains-wired units need an electricianTest and report; coordinate wired units
Legionella risk assessmentLandlord must assess the risk; no certificate requiredLandlord or someone they appointSupport it: temperatures, flushing, cylinder settings
Electrical installation reportInspected and tested at least every five years; report to tenants within 28 daysQualified electricianCoordinate with a partner

The rules behind the table come from the gas safety regulations[1], the smoke and carbon monoxide alarm regulations[2], HSE's guidance for landlords[4] and the electrical safety regulations for private rented homes[5]. By law, gas work must be done by someone in a class approved by the HSE, which in practice means Gas Safe registration[6].

Carbon monoxide alarms

Since 1 October 2022, landlords in England must ensure a carbon monoxide alarm is equipped in any room containing a fixed combustion appliance other than a gas cooker, check alarms are working on the day a new tenancy begins, and repair or replace an alarm once told it is faulty[2]. All carbon monoxide alarms must meet EN 50291-1:2018 wherever they are fitted in the UK, but the alarm rules differ between England, Wales, Scotland and Northern Ireland[7].

Dwellings in England with a carbon monoxide alarmEnglish Housing Survey
Dwellings in England with a carbon monoxide alarmColumn chart. 2023: 60%; 2024: 62%.0%20%40%60%80%2023: 60%60%20232024: 62%62%2024Dwellings in England with a carbon monoxide alarmColumn chart. 2023: 60%; 2024: 62%.0%20%40%60%80%2023: 60%60%20232024: 62%62%2024

Source: Ministry of Housing, Communities and Local Government (GOV.UK), 2024[3]

Show the data
ItemValue
202360%
202462%

Coverage is improving slowly: 62% of dwellings in England had a carbon monoxide alarm in 2024, up from 60% in 2023[3]. That leaves plenty of homes where you will find a missing, expired or badly placed alarm. Carry suitable alarms on the van, fit and test them as part of the bundle where the landlord has agreed, and record the location, type and expiry date on your report.

Legionella: practical control, not certificates

Landlords must assess the risk from legionella, but HSE says this does not need to be an in-depth assessment, most landlords can do it themselves, testing is not usually required in domestic systems and the law does not require a legionella test certificate[4]. Selling a certificate is misleading. Selling the practical measures HSE describes is honest and useful.

  • Check and record hot water temperatures, and set the cylinder to store water at 60°C[4].
  • Check cold water temperatures and that cold tanks have tight-fitting lids.
  • Identify and, where agreed, remove redundant pipework and dead legs.
  • Flush the system before a new tenancy, especially after the property has stood empty.
  • Advise tenants not to adjust the cylinder setting, and to clean and disinfect showerheads regularly.
  • Give the landlord a short written record they can keep with their own risk assessment.

Our guide to legionella risk for landlords goes into more depth.

Coordinating the rest

Electrical inspections must be done by a qualified person, at intervals of no more than five years, with the report given to tenants within 28 days and any remedial work done within 28 days[5]. If you are not an electrician, partner with one rather than stretching your own competence. Agree in writing who books the visit, who sends the report to the landlord and how remedial quotes are handled.

On every report, list each check, who carried it out, their registration and the date. Never let a landlord believe your firm did a check that a partner did.

What the gas safety part should cover

The gas safety check is the anchor of the bundle, so do it thoroughly and record it in a way the landlord can use. Treat every appliance and flue in the property as in scope, including those the tenant rarely uses, and note any appliance owned by the tenant rather than the landlord, because the duty differs.

  1. List every gas appliance and flue with its location, make and model.
  2. Record the checks and readings for each, and whether it passed.
  3. Mark any appliance that was turned off or labelled as unsafe, with the reason, and tell the landlord the same day by phone as well as in writing.
  4. Note ventilation, flue terminals and any obstruction or alteration since the last check.
  5. Add the carbon monoxide alarm results for each room with a fixed combustion appliance.
  6. State the date the next check is due.

Send the record to the landlord the same day. They need it to meet the 28-day deadline for existing tenants[1], and the sooner they have it, the sooner any follow-up work can be approved.

Getting the scheduling right

Bundles only work if the dates hold. A landlord with properties spread through the year will appreciate an offer to align them, but do it gradually: carry out each check before its due date, which brings it forward, until the properties sit in one or two runs. Never let a check slip past the 12-month interval to make the schedule neater. Keep a live register of every property, appliance and due date, and review it monthly with whoever books the work.

Building the bundle

  1. Choose the core

    Gas safety check, boiler service, carbon monoxide alarm test and water temperature checks are the usual heart of a heating firm's bundle.

  2. Add coordinated options

    Electrical inspections and smoke alarm replacement through a named electrician partner, priced and scheduled separately.

  3. Set the nation

    Rules differ between England, Wales, Scotland and Northern Ireland. Write a version of the bundle for each nation you work in.

  4. Write the report template

    One page per property: checks done, results, defects, actions required, who did each check and when the next one is due.

  5. Price per property

    With a discount structure for landlords who align several properties on one schedule, if that suits you.

  6. Schedule and remind

    Keep a register of due dates and send reminders well ahead of each one.

Worked Example: a ten-property landlord

Example (fictional): a landlord with ten flats has gas checks due at scattered dates, no record of carbon monoxide alarms and an electrical report that expires next year. A heating firm offers its annual compliance bundle and coordinates the electrical inspections with its partner electrician.

In the Example, the firm moves all ten flats onto a single two-week schedule in spring, finds three flats without the carbon monoxide alarms they need and fits them, and books the electrical inspections in the same weeks. The landlord receives one report per flat and a summary table. Two boilers flagged as near the end of their life are replaced between tenancies that summer. For changeover work between tenants, see void property works; for larger shared houses, see HMO plumbing and heating.

Words to avoid

  • Fully compliant: you cannot know every duty the landlord has, only the checks you did.
  • Legionella certificate: no such legal requirement exists[4].
  • Landlord certificate: name the specific record, such as the gas safety record.
  • Guaranteed safe: describe what you checked and found instead.

Plain, specific wording protects you and the landlord, and it is what the landlord will need if a tenant or a council ever asks questions.

Frequently asked questions

What checks should a landlord compliance package include?

For a heating firm: the gas safety check, a boiler service, carbon monoxide alarm testing and practical legionella controls, with electrical inspections coordinated through a qualified electrician.

Do landlords need a legionella certificate?

No. HSE says the law does not require a legionella test certificate, and testing is not usually required in domestic systems[4].

Where must carbon monoxide alarms be fitted in rented homes in England?

In any room with a fixed combustion appliance other than a gas cooker[2].

Can a plumber do the electrical safety report?

Only a qualified person can inspect and test the electrical installation[5]. Most heating firms coordinate it with an electrician partner.

References

  1. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 36 (opens in a new tab) ↑

  2. legislation.gov.uk (The National Archives) (2015). The Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 4 (as amended) (opens in a new tab) ↑

  3. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Housing Survey 2024 to 2025: Chapter 1, housing quality (opens in a new tab) ↑

  4. Health and Safety Executive (2026). Legionella and landlords’ responsibilities (opens in a new tab) ↑

  5. legislation.gov.uk (The National Archives) (2020). The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, regulation 3 (opens in a new tab) ↑

  6. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 3 (opens in a new tab) ↑

  7. Heating and Hotwater Industry Council (HHIC) (2025). A guide to carbon monoxide (CO) alarm legislation for heating engineers (opens in a new tab) ↑