Key takeaways
- Two separate things are required: a personal F gas qualification for the engineer and company certification for the business, which GOV.UK says includes sole traders[1][2].
- Category 2 covers installing, servicing and recovering refrigerant on systems under 3kg, or under 6kg if hermetically sealed; category 1 covers everything[1].
- Leak checks start at 5 tonnes CO2 equivalent, and labelled hermetically sealed kit under 10 tonnes is exempt[3].
- A sealed monobloc reduces refrigerant work on site but does not remove the need for qualified people when the circuit is opened, recovered or decommissioned.
- Decide by the work you will actually do in the next two years, not by what competitors advertise.
Why heating firms are suddenly asking about F gas
For most of the last twenty years a heating engineer could build a career on gas, oil and unvented hot water without touching refrigerant. Heat pumps have changed that. Almost 100,000 hydronic heat pumps were sold in the UK in 2024, a 63% rise on the year before[4], and just under 10,000 people completed a recognised heat pump qualification that year[4]. Many of those engineers then hit the same question: do I also need F gas?
The honest answer is that it depends on the equipment and the tasks, and that two different certificates are involved. Fluorinated greenhouse gases (HFC refrigerants such as R32 and R410A) are regulated because of their warming effect if they leak. The rules attach to the person doing the work and to the company offering it.
The two certificates you need to tell apart
The first is a personal qualification. GOV.UK says you need one to install new systems, service and maintain them, check for leaks, recover gas, and decommission and dispose of old systems[1]. The accredited providers it lists are City and Guilds, BESA and LCL Awards, and it notes that CITB no longer issues new F gas qualifications[1].
The second is company certification. A business that services stationary refrigeration, air conditioning or heat pump equipment containing F gas for other people must be certified by an approved body, and the guidance says this applies to sole traders too[2]. The only exemption it describes is a company that services only its own equipment[2]. Approved bodies named on GOV.UK are Refcom, F-Gas Register (Quidos) and Bureau Veritas[2].
| Category | What it allows | Who it suits |
|---|---|---|
| 1 | All activities on stationary equipment | Firms doing commercial, multi-split or larger systems |
| 2 | Install, maintain, service and recover refrigerant on systems under 3kg, or under 6kg if hermetically sealed | Domestic heat pump and split air conditioning installers |
| 3 | Recover refrigerant from systems under 3kg, or under 6kg if hermetically sealed | Engineers decommissioning small units |
| 4 | Leak checks without breaking into the refrigerant circuit | Service engineers doing inspections only |
How monobloc systems differ
Most hydronic heat pumps fitted in UK homes are monoblocs: the whole refrigerant circuit sits inside the outdoor unit, factory filled and sealed, and the installer connects water pipework rather than refrigerant lines. That is why heating engineers have been able to move into heat pumps quickly. 98% of Boiler Upgrade Scheme applications to the end of September 2026 were for air-to-water systems[5], and most of those are this type.
A sealed monobloc reduces the refrigerant work on a typical install, but it does not make F gas irrelevant. The qualification rules list servicing, leak checking, recovery and decommissioning as well as installation[1]. When a unit fails and the circuit has to be opened, or when an old unit is removed at end of life, someone qualified must do it. Before relying on the idea that a particular install needs no F gas qualification, check the manufacturer's installation instructions and ask your certification body; do not rely on a supplier's sales leaflet.
Watch the refrigerant too. Many newer monoblocs use propane (R290). Propane is not a fluorinated gas, so F gas certification does not apply to it, but it is highly flammable and needs its own training, safe-zone rules around the outdoor unit and careful handling during repairs. Split systems and air-to-air units, by contrast, almost always involve on-site refrigerant pipework and so need F gas-qualified people from day one; see our guide to air-to-air heat pumps.
Leak checks and records
Leak-check duties depend on the size of the charge in tonnes of CO2 equivalent, not kilograms. Equipment holding 5 tonnes or more needs regular leak checks, and hermetically sealed equipment under 10 tonnes is exempt if it is labelled as hermetically sealed[3]. The interval shortens as the charge grows and doubles where a leak detection system is fitted[3].
Source: legislation.gov.uk (The National Archives), 2014[3]
Show the data
| Item | Value |
|---|---|
| 5 to under 50 t CO2e | 12 months |
| 50 to under 500 t CO2e | 6 months |
| 500 t CO2e or more | 3 months |
Example (fictional): a split system holds 1.8kg of refrigerant with a datasheet global warming potential of 675. Multiply 1.8 by 675 and divide by 1,000 to get 1.2 tonnes CO2 equivalent, below the 5-tonne trigger. A large commercial split with 12kg of the same gas would hold 8.1 tonnes and need a check at least every 12 months.
Even below the threshold, keep a record of every system you install or service: site, equipment, refrigerant type, charge, any gas added or recovered, and who did the work. Your certification body will ask to see it, and it makes warranty conversations much easier.
A route to certification
List your next two years of work
Write down what you expect to fit: sealed monoblocs only, splits, air-to-air, commercial cooling. That decides which category you need.
Book the right qualification
Choose a category 2 course for domestic splits and heat pump servicing, or category 1 if you expect larger systems. Check the provider is one of those GOV.UK lists[1].
Buy or borrow the kit
Recovery machine, vacuum pump, micron gauge, gauges for your refrigerants, scales and leak detection. Assessors expect you to use them correctly.
Apply for company certification
Apply to an approved body with evidence of qualified staff, tools and procedures[2]. Do this even if you work alone.
Set up records and procedures
A template for each system record, a recovery and disposal routine, and a way to log refrigerant bought and returned.
Tell customers what you can and cannot do
Put your F gas status on quotes and service agreements so nobody assumes you will open a refrigerant circuit if you are not certified to.
Mistakes that catch heating firms out
- Assuming the company certificate covers a new engineer. Each person doing the work needs their own qualification, and the company certificate depends on having qualified people.
- Letting the company certificate lapse while the engineer’s qualification is still valid, or the other way round. Put both renewal dates in the office diary with a reminder two months ahead.
- Venting refrigerant during a repair because the recovery machine is on another job. Deliberate release is exactly what the rules exist to prevent.
- Buying a split system over a trade counter and asking someone else to commission it under their certificate. If anything goes wrong, the paperwork will not support you or the customer.
- Not recording gas added during repairs. A record that shows the charge creeping up each year is evidence of a leak that should have been found and fixed.
A simple habit fixes most of this: add an F gas line to your job sheet template with refrigerant type, charge, gas added or recovered and the engineer’s certificate number. It takes a minute on site and answers most of the questions a manufacturer, customer or certification body will ask later. It also gives you the service history you need when a customer moves house and the buyer asks what was done.
When subcontracting makes more sense
Not every firm needs to go all the way. If your heat pump work is almost all sealed monoblocs and you rarely see a refrigerant fault, a written arrangement with a certified refrigeration firm for repairs and end-of-life recovery can be cheaper than holding the certification yourself. Agree response times, who talks to the customer, and how warranty claims are handled before you need them.
- Certify in-house if you fit splits, air-to-air or multi-split systems, or plan to service other installers' heat pumps.
- Subcontract if refrigerant work is rare, your engineers are fully booked, and a reliable certified partner works locally.
- Review the decision each year as your mix of work changes and your ACS and heat pump qualifications come up for renewal.
Whichever you choose, be precise in your marketing. Saying you are F gas certified when only one engineer holds the personal qualification, or the company certificate has lapsed, is the kind of claim that unravels quickly when a customer or manufacturer checks.
Frequently asked questions
Do I need F gas certification to install a monobloc heat pump?
The guidance lists installation, servicing, leak checks, recovery and decommissioning as activities needing a qualification[1]. Sealed monoblocs reduce on-site refrigerant work, so check the manufacturer's instructions and your certification body for the specific unit, and make sure qualified people handle any work on the circuit.
Does a sole trader need F gas company certification?
Yes. GOV.UK states that companies, including sole traders, servicing equipment for others must be certified by an approved body[2].
Which F gas category do I need for domestic split systems?
Category 2 covers installing, maintaining, servicing and recovering refrigerant on systems holding under 3kg, or under 6kg if hermetically sealed[1]. Check the charge on the data plate.
Do propane heat pumps need F gas?
Propane (R290) is not a fluorinated gas, so F gas rules do not apply to it, but it is highly flammable and needs separate training and safe handling.
References
GOV.UK (2026). Qualifications required to work on equipment containing F gas (opens in a new tab) ↑
GOV.UK (2026). Certification for companies working on equipment containing F gas (opens in a new tab) ↑
legislation.gov.uk (The National Archives) (2014). Regulation (EU) No 517/2014 on fluorinated greenhouse gases, Article 4: Leak checks (as retained in UK law) (opens in a new tab) ↑
Heating and Hotwater Industry Council (HHIC) (2024). Bumper year for UK heat pumps (opens in a new tab) ↑
Department for Energy Security and Net Zero (2026). Boiler Upgrade Scheme (BUS) monthly statistics: England and Wales, September 2026 (opens in a new tab) ↑