Key takeaways
- Under the October to December 2026 price cap, electricity costs about 3.3 times as much per kWh as gas[1], which sets the efficiency a heat pump needs to beat a boiler.
- In the Example here, a heat pump needs a seasonal efficiency of about 3 to match a 90% efficient gas boiler on unit costs alone.
- Dropping the gas supply removes a daily standing charge of 29.68p[1], and smart tariffs can save more[2].
- Give ranges with stated assumptions, never a single promised saving.
Why honest numbers win the job
Running costs are the question behind most heat pump enquiries. Customers have read that heat pumps are cheaper to run and also that they are more expensive, and both can be true depending on the home, the design and the tariff. Energy prices are a live worry: 69% of UK businesses expressed some concern about energy prices in late October 2026[3], and households feel the same pressure. The installer who explains the numbers clearly, with the assumptions on the table, is the one customers trust.
An honest explanation also protects you. A promised saving that does not appear becomes a complaint; a range with clear assumptions becomes a conversation about which assumption changed.
The three numbers that decide running costs
- Heat demand: how many kWh of heat the home needs a year for space heating and hot water, from your heat loss calculation and the household's use.
- Efficiency: a boiler's seasonal efficiency, or a heat pump's seasonal coefficient of performance, often written SCOP, which is the heat delivered per unit of electricity over a year.
- Unit prices: the cost per kWh of gas or electricity on the customer's tariff, plus standing charges.
Heat demand is the same whichever system heats the home. What changes is how much fuel each system needs to deliver it and what that fuel costs. A heat pump with a SCOP of 3 delivers three units of heat for each unit of electricity over the year. A good condensing boiler delivers a little less than one unit of heat for each unit of gas.
Today's prices and the price ratio
From 1 October to 31 December 2026, the energy price cap for Direct Debit customers averages 26.32p per kWh for electricity with a daily standing charge of 54.83p, and 7.97p per kWh for gas with a standing charge of 29.68p[1]. In July to September 2026 the rates were 26.11p and 7.33p[1]. Ofgem notes there is no VAT on electricity from 1 October 2026 to 31 March 2027[1].
- July to September 2026
- October to December 2026
Source: Ofgem, 2026[1]
Show the data
| Item | July to September 2026 | October to December 2026 |
|---|---|---|
| Electricity | 26.11 p/kWh | 26.32 p/kWh |
| Gas | 7.33 p/kWh | 7.97 p/kWh |
Divide the electricity rate by the gas rate and you get the price ratio, about 3.3 for October to December 2026. That single number explains most of the running cost debate. The higher the ratio, the more efficient a heat pump has to be to beat gas on unit costs; the lower it is, the easier it becomes. Check the current cap and the customer's own tariff before every estimate, because both change.
The break-even efficiency
Example: assume a gas boiler with a seasonal efficiency of 90%. Each kWh of heat costs 7.97p divided by 0.9, about 8.86p. A heat pump's cost per kWh of heat is 26.32p divided by its SCOP. The two are equal when the SCOP is about 3.0. Below that, on these prices, the heat pump costs more per unit of heat; above it, less. That is the honest headline: a well-designed, well-commissioned heat pump running at low flow temperatures can beat gas, and a poorly designed one may not.
This is why design quality and running costs are the same conversation. Radiators sized for low flow temperatures, correct heat pump sizing and good controls set-up all push the SCOP up. Your sizing decisions are running cost decisions.
Example: one home, three outcomes
| Scenario (Example) | Fuel used a year | Unit cost a year |
|---|---|---|
| Gas boiler, 90% efficient | 13,333 kWh gas | £1,063 |
| Heat pump, SCOP 2.5 | 4,800 kWh electricity | £1,263 |
| Heat pump, SCOP 3.0 | 4,000 kWh electricity | £1,053 |
| Heat pump, SCOP 3.5 | 3,429 kWh electricity | £902 |
Example: the same home's bill can rise, stay level or fall depending on the efficiency the system achieves. Showing all three rows is more honest, and more persuasive, than showing only the best one. It also gives you a way to explain why your design choices, such as larger radiators, cost a little more up front.
Standing charges change the sum
If the customer removes their gas supply altogether, they stop paying the gas standing charge. At 29.68p a day[1], that is about £108 a year. If they keep gas for cooking, they keep the standing charge. Include this line explicitly, because it is often the difference between a heat pump looking slightly dearer and slightly cheaper to run.
Tariffs and batteries
Multi-rate tariffs such as Economy 7 charge one rate in peak hours and another off peak[1], and newer time-of-use tariffs work on the same idea with more flexibility. A heat pump that can run more in cheaper periods lowers the average price per kWh and so the cost per unit of heat. The Warm Homes Plan estimates that households who switch to a time-of-use tariff and charge a battery off-peak could save up to an additional £300, depending on the home and circumstances[2]. Treat that as an upper estimate, not a promise, and point customers to heat pump tariff advice before they switch.
Oil and LPG customers
For off-gas customers the comparison is different. Heating oil and LPG are not covered by the energy price cap[4], so use the customer's own recent fuel bills rather than a national figure, and convert litres to kWh using their supplier's information. Price swings in those fuels can be large, which some customers value avoiding as much as the average saving.
Bills follow the seasons
Warn customers that monthly bills will not be even. UK household gas demand in the first quarter of 2026 was more than five times the level in the third quarter of 2025[5], and heat pump electricity use follows the same seasonal pattern. A January bill compared with an August one will look alarming unless you explained this at handover.
Do not forget hot water
Hot water is often a large share of a heat pump's annual electricity use, and it is usually produced at a higher temperature than space heating, so the efficiency for hot water is lower. Include it as a separate line in your estimate, based on the number of occupants and their habits, rather than folding it into one average figure. If the system runs periodic high-temperature cycles to protect the cylinder, account for those too. Customers who understand that the hot water side has its own efficiency are less surprised by a summer bill when the heating is off.
The conversation, step by step
Start with their bills
Ask for a year of gas or oil use and their current tariff.
Show the three numbers
Heat demand, efficiency and unit prices, in plain words.
Give a range
Show low, central and high efficiency outcomes, as in the Example.
Add standing charges and tariffs
Show what changes if they drop gas or move to a time-of-use tariff.
Write down the assumptions
Put prices, dates and efficiency assumptions on the estimate.
Promise the design, not the bill
Commit to the design standards that make good efficiency achievable, rather than a fixed saving.
A written estimate that stands up later
Put the running cost estimate in writing, on a single page attached to the quote. The aim is that, a year later, anyone can see what you assumed and why the bill came out as it did.
- Annual heat demand for heating and hot water, and where the figures came from.
- The efficiency assumptions for the existing system and the heat pump, as low, central and high cases.
- The unit rates and standing charges used, with the date of the price cap or tariff.
- A line showing the effect of removing the gas supply, if relevant.
- A line showing a typical time-of-use tariff, labelled as an illustration.
- A clear statement that actual costs depend on weather, use and future prices.
What not to say
- Heat pumps are always cheaper to run.
- You will save a set amount every year.
- Your bills will halve.
- The tariff we recommend will stay the same.
- Any figure without the date of the prices it uses.
Frequently asked questions
Is a heat pump cheaper to run than a gas boiler?
It depends on the efficiency the system achieves and the prices paid. At October to December 2026 cap rates, a heat pump needs a seasonal efficiency of about 3 to match a 90% efficient gas boiler on unit costs.
What is SCOP?
The seasonal coefficient of performance: the heat a heat pump delivers over a year divided by the electricity it uses.
Does removing the gas supply save money?
It removes the gas standing charge, 29.68p a day under the October to December 2026 cap, if the customer no longer needs gas for anything else.
Should I promise a running cost saving?
No. Give a range with dated prices and stated assumptions, and commit to the design quality that makes good efficiency possible.
References
Ofgem (2026). Energy price cap unit rates and standing charges (opens in a new tab) ↑
Department for Energy Security and Net Zero (GOV.UK) (2026). Warm Homes Plan (opens in a new tab) ↑
Office for National Statistics (2026). Business insights and impact on the UK economy: latest bulletin (opens in a new tab) ↑
Heating and Hotwater Industry Council (HHIC) (2026). HHIC and OFTEC urge Government to back hybrid heating systems to support off-grid households (opens in a new tab) ↑
Department for Energy Security and Net Zero (2026). Energy Trends: UK gas, ET 4.1 natural gas supply and consumption (quarterly), September 2026 (opens in a new tab) ↑