Boilers heating

Weather compensation: explaining it to customers

Explain weather and load compensation in plain words: how the heat curve works, what customers notice, OpenTherm, set-up steps and common complaints.

Ava research teamPublished 6 min read

On this page
  1. The one-sentence explanation
  2. Why it matters: most heating days are mild
  3. What the evidence says about lower flow temperatures
  4. Weather, load and the protocols that link them
  5. Setting up the heat curve
  6. What customers will notice, and what to say
  7. Worked Example: tuning a curve in the first winter
  8. Talking about running costs honestly
  9. When compensation is a poor fit
  10. Servicing a compensated system
  11. Frequently asked questions
  12. References

Key takeaways

  • Weather compensation lowers the flow temperature on mild days and raises it on cold ones; most of the heating season is mild, which is why it helps[1].
  • Weather and load compensation are both qualifying Boiler Plus measures for combis in England; TPI is not load compensation[2].
  • Testing at the Salford Energy House found that cutting flow temperature from 80°C to 60°C saved 12% of the gas used to heat the house, but warm-up took longer[3].
  • Set a heat curve with the customer, explain that radiators will feel warm rather than hot, and follow up after the first cold week.

The one-sentence explanation

Customers do not need control theory. A sentence that works: 'A small sensor outside tells the boiler how cold it is, so on mild days it sends cooler water to the radiators and on cold days hotter water, instead of running flat out all the time.' Most people understand that immediately, and it sets up the conversation about what they will notice.

Load compensation is the indoor cousin. The room thermostat tells the boiler how far the room is from the temperature set, and the boiler adjusts its flow temperature to suit, rather than switching on and off. Some boilers combine both.

Why it matters: most heating days are mild

Radiators and boilers are sized for the coldest days, but those are a small part of the year. UK household gas demand in January to March 2026 was 109,126 GWh against 19,636 GWh in July to September 2025[1], and within the heating season, autumn and spring days need far less heat than a January cold snap.

UK household gas demand, summer and winter quartersHeating systems are sized for the coldest days but spend most of the year at part load
UK household gas demand, summer and winter quartersColumn chart. July to September 2025: 19,636 GWh; January to March 2026: 109,126 GWh.0 GWh50,000 GWh100,000 GWh150,000 GWhJuly to September 2025: 19,636 GWh19,636 GWhJuly to September 2025January to March 2026: 109,126 GWh109,126 GWhJanuary to March 2026UK household gas demand, summer and winter quartersColumn chart. July to September 2025: 19,636 GWh; January to March 2026: 109,126 GWh.0 GWh50,000 GWh100,000 GWh150,000 GWhJuly to September 2025: 19,636 GWh19,636 GWhJuly toSeptember2025January to March 2026: 109,126 GWh109,126 GWhJanuary toMarch 2026

Source: Department for Energy Security and Net Zero, 2026[1]

Show the data
ItemValue
July to September 202519,636 GWh
January to March 2026109,126 GWh

A boiler running at a fixed high flow temperature on a mild October day sends very hot water to radiators that only need to be lukewarm, then cycles off when the room overshoots. A compensated boiler sends cooler water for longer. Cooler return water lets a condensing boiler recover more heat from its flue gases, which is where the efficiency comes from.

What the evidence says about lower flow temperatures

Nesta's testing at the Salford Energy House, a full-size test house in a climate chamber, found that lowering a combi's flow temperature from 80°C to 60°C saved 12% of the gas used to heat the house[3]. It also found the trade-off: morning heat-up times went from 23 minutes to 37 minutes[3].

12%

Gas used to heat the test house saved by lowering flow temperature from 80°C to 60°C[3]

Weather compensation automates that idea and goes further on mild days, when it can run lower still. The warm-up trade-off is the thing to explain in advance, because it is what customers notice first.

Compensation types and how they work
TypeWhat it readsHow it adjustsNotes
Weather compensationOutdoor temperature sensorSets flow temperature on a heat curveRobust, little user input
Load compensationRoom temperature against set pointModulates flow temperature as the room approaches set pointNeeds compatible thermostat and boiler
Weather plus room influenceBothCurve adjusted by room feedbackOften the best comfort
TPI on/off controlRoom temperatureSwitches boiler on and off in timed cyclesNot load compensation for Boiler Plus

For gas combis in England, weather compensation and load compensation are two of the four qualifying Boiler Plus measures, alongside flue gas heat recovery and smart thermostats with automation and optimisation[2]. Approved Document L lists the same four[4]. The government's guidance is explicit that TPI on/off control does not count as load compensation[2].

Load compensation depends on the thermostat and boiler talking to each other, through OpenTherm or a manufacturer's own protocol. Check compatibility before quoting; a thermostat that only sends on/off signals will not modulate the boiler, however clever its app.

Setting up the heat curve

  1. Position the sensor

    Fit the outdoor sensor on a north or north-west wall, out of direct sun, away from flue terminals, windows and heat sources, at a height where it reads air temperature.

  2. Start from the design

    Use the flow temperature the radiators need on the coldest design day and the boiler maker's curve options to pick a starting curve.

  3. Set limits

    Set the maximum flow temperature to what the radiators actually need, not the boiler's maximum.

  4. Add room influence if available

    Where the thermostat supports it, enable room feedback so the curve self-corrects.

  5. Explain the first week

    Tell the customer that you may need to adjust the curve once they have lived with it in colder weather.

  6. Adjust from feedback

    If the house is cool on cold days, raise the curve slightly; if it overshoots on mild days, lower it.

What customers will notice, and what to say

  • 'The radiators are only warm.' That is the system working as designed; the rooms should still reach temperature.
  • 'The heating seems to be on all the time.' It runs longer at a gentler temperature instead of short bursts.
  • 'It takes longer to warm up in the morning.' Yes, especially from cold; bringing the start time forward or using a smaller overnight setback helps.
  • 'It was fine last month and now it is cold.' The curve may need a small upward adjustment for colder weather.

Most compensation complaints happen in the first cold snap after installation. A follow-up call during that week turns a likely complaint into a quick curve adjustment.

Worked Example: tuning a curve in the first winter

Example. A four-bedroom semi gets a combi with a manufacturer weather sensor. The heat loss calculation and radiator sizes suggest the house needs around 60°C flow on the coldest days. The engineer selects a matching curve, caps the maximum flow temperature accordingly and explains the slower warm-up to the owners.

Example. In the first frosty week the owners report the back bedroom is cool by evening. The engineer raises the curve one step and suggests bringing the morning start forward. On the follow-up call a week later the house is comfortable and the owners have stopped turning the thermostat up and down, which was undoing the benefit.

Talking about running costs honestly

Customers will ask how much they will save. The truthful answer is that it depends on the house, the radiators, how they heat the home and what the boiler was doing before. Testing shows lower flow temperatures can make a real difference, but a household that already ran a low flow temperature, or one that heats only a couple of hours a day, will see less.

A fair way to put it: 'This lets the boiler run in its most efficient way for most of the year. Homes like yours often use less gas, but I cannot promise a figure because it depends on how you use the heating. What I can promise is steadier warmth.'

  • Do not quote savings percentages from testing as if they apply to this house.
  • Do encourage the customer to compare meter readings over a similar period next year if they are curious.
  • Explain that turning the thermostat up and down a lot undermines the benefit.
  • Mention that the same approach suits a future heat pump, which also works best at low flow temperatures.

When compensation is a poor fit

  • Homes heated only in short bursts with long cold periods in between, where the customer expects rapid warm-up.
  • Systems with badly undersized radiators that cannot heat rooms without a high flow temperature; fix the emitters first.
  • Customers who will not accept slower warm-up and are likely to disable the feature.
  • Some system boiler and cylinder setups where hot water priority and compensation need careful configuration to keep stored water at a safe temperature.

In these cases, be honest. Recommend a different Boiler Plus measure for a combi if needed, or explain what would need to change for compensation to work well. Record the curve, maximum flow temperature and sensor position on the commissioning record. See lowering flow temperature and smart controls advice.

Servicing a compensated system

Compensation is easy to break by accident at a service. An engineer who resets the boiler to factory settings, disconnects the sensor while working or turns the flow temperature up to make a radiator 'feel hotter' can undo the setup without the customer knowing.

  • Check the outdoor sensor is still connected and reading a sensible temperature.
  • Confirm the heat curve and maximum flow temperature match the commissioning record.
  • Ask the customer whether the house has been comfortable in cold spells before changing anything.
  • Record any change you make and why, so the next engineer understands the settings.

If a customer has disabled compensation, ask why. Often the cause is a single cold morning that a small curve change or an earlier start time would have solved.

Frequently asked questions

Does weather compensation save money?

Running at lower flow temperatures improves condensing efficiency, and testing has shown meaningful gas savings from lower flow temperatures. Actual savings vary with the home and how it is used, so avoid promising a figure.

Is weather compensation the same as a smart thermostat?

No. Weather compensation adjusts flow temperature from an outdoor sensor. A smart thermostat may or may not offer compensation; check its functions.

Where should the outdoor sensor go?

Usually on a north or north-west wall, out of direct sun and away from flues, windows and other heat sources.

Why does my heating take longer to warm up now?

Lower flow temperatures heat rooms more gently. Bringing the start time forward or reducing overnight setbacks usually solves it.

References

  1. Department for Energy Security and Net Zero (2026). Energy Trends: UK gas, ET 4.1 natural gas supply and consumption (quarterly), September 2026 (opens in a new tab) ↑

  2. Department for Business, Energy and Industrial Strategy (GOV.UK) (2018). Boiler Plus: new standards for domestic boiler installations from April 2018, frequently asked questions (opens in a new tab) ↑

  3. Nesta (2022). Salford Energy House boiler flow temperature testing: initial report (opens in a new tab) ↑

  4. Ministry of Housing, Communities and Local Government (GOV.UK) (2023). Approved Document L, Volume 1: Dwellings (2021 edition incorporating 2023 amendments) (opens in a new tab) ↑