Boilers heating

Lowering boiler flow temperature: advice that avoids complaints

When lowering a boiler's flow temperature saves gas and when it causes complaints: what the evidence shows, a setting routine and customer scripts.

Ava research teamPublished 7 min read

On this page
  1. Why this question keeps coming up
  2. What the evidence actually shows
  3. Who benefits and who complains
  4. A routine for setting it properly
  5. Balancing: the step that makes lower temperatures work
  6. Where the building regulations fit
  7. Combis, system boilers and hot water
  8. Worked Example: two calls in the same week
  9. When a customer has already changed it themselves
  10. Scripts for the conversation
  11. Frequently asked questions
  12. References

Key takeaways

  • In a controlled test house, cutting combi flow temperature from 80°C to 60°C saved 12% of heating gas, with slower morning warm-up[1].
  • In a large real-world trial, a one-off email telling households to set 60°C made no significant difference to gas use; specific, timed advice produced a small saving[2].
  • The gap between those results is the case for engineers setting flow temperature properly at the boiler, matched to the radiators, rather than leaving it to a leaflet.
  • Stored hot water must stay at a safe temperature; flow temperature advice applies to space heating.

Why this question keeps coming up

Since energy prices rose, customers have read that turning down the boiler's flow temperature cuts bills. Some have done it themselves and been pleased; others have done it and rung you because the house will not warm up. Both groups are right about their own homes, and your advice needs to explain why.

It affects most of your customers, because most homes have a combi on which the heating flow temperature is a simple dial or menu setting. In 2024, 63% of homes in England had a condensing combination boiler[3].

What the evidence actually shows

In Nesta's testing at the Salford Energy House, lowering a combi's flow temperature from 80°C to 60°C saved 12% of the gas used to heat the house[1]. The cost was comfort at the margins: morning heat-up time rose from 23 to 37 minutes[1].

Morning heat-up time in the Salford Energy House testNesta initial report, October 2022
Morning heat-up time in the Salford Energy House testComparison. 80°C flow temperature: 23 min; 60°C flow temperature: 37 min.23 min80°C flow temperature80°C flow temperature: 23 min37 min60°C flow temperature60°C flow temperature: 37 minMorning heat-up time in the Salford Energy House testComparison. 80°C flow temperature: 23 min; 60°C flow temperature: 37 min.23 min80°C flow temperature80°C flow temperature: 23 min37 min60°C flow temperature60°C flow temperature: 37 min

Source: Nesta, 2022[1]

Show the data
ItemValue
80°C flow temperature23 min
60°C flow temperature37 min

Real homes are messier. Nesta later ran a randomised trial with about 61,000 users of an energy app. A one-off email advising them to set their flow temperature to 60°C produced no statistically significant difference in daily gas use, while month-specific advice produced a small but significant reduction of about 0.4%[2]. The trial found no difference in reported thermal discomfort between groups[2].

About 61,000

App users in Nesta's randomised trial of boiler flow temperature advice[2]

Read together, the results say two things. The physics works: lower flow temperatures make condensing boilers more efficient. But telling people to do it in a general message is weak, because many cannot find the setting, change the wrong one, or reverse it at the first cold morning. An engineer who sets it properly, explains it and checks the radiators can deliver much more of the benefit.

Who benefits and who complains

When a lower flow temperature works and when it backfires
SituationLikely result of lowering flow temperatureAdvice
Well-insulated home with generous radiatorsComfortable and more efficientLower it and leave it
Average home, heating on for long periodsComfortable with slightly longer warm-upLower it, adjust start times
Home heated in short bursts from coldSlow warm-up, complaints likelyLower modestly, or longer heating periods
Rooms with undersized radiatorsThose rooms stay coolUpgrade radiators or keep a higher setting
Older or unwell occupant needing steady warmthRisk if rooms underheatPrioritise warmth; lower only if rooms stay comfortable
System boiler with cylinderHot water may suffer if primary temperature is too lowTreat heating and hot water settings separately

The deciding factor is usually the radiators. A room whose radiator is just big enough at a high flow temperature will not reach comfort at a lower one. Spot those rooms before you change anything, and the complaint disappears from the conversation.

A routine for setting it properly

  1. Ask how the home is heated

    Hours of heating, rooms used, who is at home and whether anyone feels the cold.

  2. Check the radiators

    Look for undersized or poorly performing radiators, and balance the system if some rooms heat much faster than others.

  3. Find the right control

    On a combi, identify the central heating flow setting, not the hot water setting, and show the customer which is which.

  4. Lower in small steps

    Reduce the setting a step at a time rather than in one jump, and agree to review after a cold spell.

  5. Adjust timings

    Bring the heating start forward or reduce long setbacks to offset slower warm-up.

  6. Protect the hot water

    On cylinder systems, keep stored water at a safe temperature in line with the cylinder maker's instructions and Legionella guidance.

  7. Record it

    Write the setting and the reason on the service or commissioning record.

Balancing: the step that makes lower temperatures work

At a high flow temperature, a poorly balanced system can hide its faults. Radiators near the boiler get most of the flow, but the water is hot enough that distant rooms still warm up eventually. Turn the temperature down and the imbalance shows: the far bedroom stays cool while the hallway radiator is too hot to touch.

  • Open all radiator valves fully, run the heating from cold and note which radiators warm first.
  • Close down the lockshield valves on the fastest radiators until each one shows a similar temperature drop from flow to return.
  • Recheck the slowest rooms after balancing before deciding they need bigger radiators.
  • Record the balancing on the service record so the next engineer does not undo it.

Balancing takes time, so price it honestly when it is a separate job. It often solves the cold room complaint on its own, and it is the foundation for any lower temperature setting, compensation or future heat pump.

Where the building regulations fit

For new or fully replaced wet heating systems, Approved Document L asks for the whole system to be sized to work at a maximum flow temperature of 55°C or lower[4]. That is a design rule for new systems, not a setting rule for existing ones, but it shows the direction of travel. Radiators sized for lower temperatures make this advice easy; radiators sized decades ago for very hot water make it harder.

If a customer is planning radiator upgrades, an extension or a future heat pump, mention that larger radiators now make lower flow temperatures comfortable later.

Combis, system boilers and hot water

On most combis, heating flow and hot water outlet temperatures are separate settings. Lowering the heating setting does not affect showers. Customers often confuse the two, so show them the difference on the boiler itself.

On system and regular boilers, the boiler heats the cylinder through the same primary water. Too low a setting can leave the cylinder unable to reach a safe storage temperature. Some boilers handle this by running a higher temperature when heating the cylinder; check the controls, and never advise a setting that compromises stored hot water safety.

Worked Example: two calls in the same week

Example. A customer lowered their combi's heating flow temperature after reading about it, and now the back bedroom never warms up. The engineer finds a single small radiator in that room, well below what its heat loss needs at the new setting. The engineer raises the setting slightly as a stopgap and quotes a larger radiator, explaining that once it is fitted the lower setting can be restored for the whole house.

Example. At a service, another customer still has the factory setting near maximum. The house has recent radiators and good loft insulation. The engineer lowers the heating flow temperature in two steps, moves the morning start earlier, shows the customer the setting and calls back after the first frost. The customer reports no difference in comfort.

When a customer has already changed it themselves

Many calls start with a customer who has turned the dial down after reading about it and is now unhappy. Treat it as a useful starting point rather than a mistake. They have already shown they are willing to change how the system runs; your job is to make the change work.

  1. Check which setting they changed. Some customers lower the hot water setting by mistake and wonder why showers feel cooler.
  2. Ask which rooms are uncomfortable and when.
  3. Inspect the radiators in those rooms and the balancing of the system.
  4. Adjust the setting or the heating times as a short-term fix.
  5. Quote any radiator or balancing work needed for the lower setting to work everywhere.

Explaining what happened builds trust. The customer leaves understanding their system better, and you have usually earned the next service.

Scripts for the conversation

  • 'This dial sets how hot the water going to your radiators is. Lower is more efficient for your boiler, as long as your rooms still get warm.'
  • 'Your showers are controlled separately, so this will not affect your hot water.'
  • 'It may take a little longer to warm the house in the morning, so I have moved the start time earlier.'
  • 'If any room feels cold in the first cold week, ring me and I will adjust it rather than you turning it right back up.'
  • 'This bedroom radiator is too small to work at a lower temperature. Upgrading it would let the whole house run cooler.'

For customers who are older, unwell or struggling with bills, comfort and safety come first. Lower the setting only if the rooms they use still reach a comfortable temperature, and say so clearly.

For the automatic version of this advice, see weather compensation explained. For broader energy conversations, see serving customers struggling with bills.

Frequently asked questions

What flow temperature should I set on a combi?

It depends on the radiators and the home. Lower is more efficient as long as every room still reaches comfort. Lower in small steps, adjust heating times and review after a cold spell.

Does lowering flow temperature affect hot water?

On most combis, no; hot water has its own setting. On system and regular boilers, the cylinder must still reach a safe storage temperature, so check the controls.

Why did my house get colder after I turned it down?

Usually because one or more radiators are too small for the lower temperature, or the heating periods are too short. Both can be fixed.

Is there evidence it saves gas?

Controlled testing found a 12% saving on heating gas when flow temperature fell from 80°C to 60°C. Results in real homes vary, and general advice alone had little measurable effect in a large trial.

References

  1. Nesta (2022). Salford Energy House boiler flow temperature testing: initial report (opens in a new tab) ↑

  2. Nesta (2023). The impact of boiler optimisation on gas consumption and household comfort (opens in a new tab) ↑

  3. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Housing Survey 2024 to 2025: Chapter 2, energy efficiency (opens in a new tab) ↑

  4. Ministry of Housing, Communities and Local Government (GOV.UK) (2023). Approved Document L, Volume 1: Dwellings (2021 edition incorporating 2023 amendments) (opens in a new tab) ↑