Key takeaways
- A diverter sends surplus solar electricity to the immersion heater instead of exporting it, so the cylinder becomes a cheap store of energy.
- Solar demand is strong: MCS recorded 210,000 certified renewable installations in the first half of 2026, and one in three 2026 installations combined more than one technology[1].
- The plumber's part is the cylinder: survey, immersion, thermostat, valves and sometimes a new cylinder; the diverter wiring belongs to a competent electrician.
- A diverter makes most sense where the home has a cylinder, real summer surplus and a low export rate compared with the cost of heating water another way.
- Make sure the store still reaches 60°C regularly[2], because diverted solar can leave a cylinder sitting warm rather than hot.
What a diverter does
A solar PV diverter watches the electricity flowing at the meter. When the panels generate more than the house is using, instead of letting the surplus flow to the grid, it sends that power to the immersion heater in the hot water cylinder, varying the amount to match the surplus. The cylinder becomes a battery for heat: water warmed at midday is still hot in the evening.
Exporting is not worthless. Under the Smart Export Guarantee, licensed suppliers pay small generators for clean power they send to the grid, and the tariff must always be above zero[3]. The case for a diverter is that the value of using surplus to heat water you would otherwise heat with gas, oil or bought electricity is often higher than the export payment. Whether it is depends on the customer's tariff and how they heat water now.
That makes the diverter a conversation about the whole hot water system, not just a box on the wall. It is a natural fit for a plumber who already understands cylinders, immersions and the way households use hot water.
Why plumbers are being asked about it
Solar is growing quickly. MCS recorded 210,000 certified renewable installations in the UK in January to June 2026, up 17% on the previous record start to a year, and one in three installations in 2026 combined more than one renewable technology in the same home[1]. Many of those homes already have a cylinder, and many owners are asking what else their panels can do.
- Combined more than one technology 33%
Source: MCS (Microgeneration Certification Scheme), 2026[1]
Show the data
| Item | Value |
|---|---|
| Combined more than one technology | 33% |
Off-gas homes are a strong market. Around four million UK homes rely on heating oil or LPG, which are not covered by the energy price cap[4]. For these households, keeping the oil boiler off for hot water through the summer is an easy saving to explain.
Where the plumber fits and where the electrician fits
| Task | Plumber | Electrician |
|---|---|---|
| Survey the cylinder, immersion boss and controls | Leads | Advises on supply and wiring |
| Replace a failed or unsuitable immersion element | Fits the element | Wires and tests it if needed |
| Install the diverter and current sensor | Not normally | Leads, to Building Regulations requirements |
| Replace or upgrade the cylinder | Leads, including unvented competence | Wires immersion and controls |
| Set temperatures and check the high-temperature cycle | Leads | Supports with timers and controls |
| Handover to the customer | Joint | Joint |
Electrical work has its own competence and notification rules, and homeowners do not need to apply for Building Regulations approval themselves when they use an installer registered with a competent person scheme[5]. Agree in writing which of you notifies what, and make sure the customer receives every certificate.
When a diverter is worth it
- The home has a hot water cylinder with an immersion heater. With a combi and no cylinder, there is nothing to divert to.
- The panels produce a real surplus at midday in spring and summer. A small array that the house already uses fully will divert little.
- The household uses a fair amount of hot water: a family of four gets more value than a single person who is out all day.
- Hot water currently comes from oil, LPG or electricity bought at a higher price than the export rate.
- There is no battery or electric vehicle already soaking up the surplus. Where there is, a diverter takes only what is left over.
- For heat pump homes, compare the diverter with simply running the heat pump for hot water during sunny hours, which may make better use of each unit of surplus.
If you cannot explain the saving with the customer's own tariff and hot water habits, do not fit the diverter yet.
Is the cylinder up to it?
Many diverter jobs reveal a cylinder that has been ignored for years. The immersion may not have been used since the boiler was fitted, the element may be scaled or failed, and an old copper cylinder may have thin insulation that loses much of the solar heat overnight. Check before you promise anything.
- Is there an immersion boss, and is the element working, the right length and suitable for daily use?
- Is the cylinder well insulated, or would a jacket or replacement keep the solar heat for longer?
- Is the cylinder large enough to store a useful amount of midday surplus for the household?
- Are the valves, vent and expansion arrangements sound, especially on older vented systems?
- Would a replacement cylinder with a dedicated solar or second immersion position serve the customer better?
Where a new cylinder is the better answer, say so, and quote it as an option alongside the simpler job. Customers appreciate the choice, and many take the better system once they see why.
Legionella and temperatures
A diverter can leave a cylinder at whatever temperature the surplus allows. On a cloudy week, the water may sit warm for days. HSE guidance is to store hot water at 60°C or above and reach 50°C at the outlets within one minute[2]. Make sure the system still reaches that temperature regularly, by a boiler, heat pump or timed immersion boost if the sun does not.
- Set the immersion thermostat to a safe storage temperature and check it at commissioning.
- Keep the boiler or heat pump hot water timer active as a backstop, or add a timed boost on the diverter.
- Fit or check a thermostatic mixing valve where higher storage temperatures increase scald risk.
- Explain to the customer why the backstop matters, so they do not switch it off to save fuel.
From survey to handover
Ask about the panels and the tariff
Array size, inverter, any battery or EV charger, the export arrangement and the customer's import tariff.
Survey the cylinder
Type, size, condition, immersion boss position, element condition and how hot water is heated now.
Agree the scope with the electrician
Who supplies and fits the diverter, sensor and any new wiring, and who notifies the work.
Quote clearly
Separate lines for plumbing and electrical work, any new cylinder, and a short explanation of expected benefits with assumptions.
Install and commission
Check the immersion receives diverted power when the panels export, and that the backstop heating still works.
Hand over
Show the customer the diverter display, explain the backstop and leave a simple note on what to expect in winter.
Worked Example: an oil-heated family home
Example (fictional): a family of four in an oil-heated house has a 4kWp solar array and a 150-litre vented cylinder with an old immersion element. They export most of their midday generation and heat water with the oil boiler all year.
In the Example, the plumber replaces the immersion element and thermostat, checks the cylinder is sound and leaves the oil boiler timer set for a short evening top-up. The electrician installs the diverter and sensor. Through late spring and summer the cylinder is heated mostly from surplus solar, and the boiler barely fires for hot water. The family saves oil in the months when they would otherwise run the boiler only for hot water, and the plumber books them for an oil service in September.
Callbacks to expect, and how to avoid them
- No hot water on a dull week because the boiler or heat pump timer was switched off. Leave the backstop set and explain why.
- The diverter appears to do nothing in winter. Tell the customer at handover that winter surplus is small and the display will show it.
- Battery and diverter fighting over the surplus. Agree the priority order with the electrician and set it at commissioning.
- Immersion element failing early on hard water. Recommend a suitable element and mention it in the service notes.
A one-page note covering these points, left by the cylinder, prevents most of them.
Making it part of your offer
Diverters are a small job on their own, but they lead to other work: cylinder replacements, unvented upgrades, controls and, in time, heat pumps. Build a partnership with one or two electricians who do solar, and offer the hot water side as a package. Our guides to solar thermal, unvented cylinders and low-carbon marketing help you present it honestly.
Frequently asked questions
What is a solar PV diverter?
A device that sends surplus solar electricity to the immersion heater in a hot water cylinder instead of exporting it to the grid.
Is a diverter better than the Smart Export Guarantee?
Not always. Export payments under the SEG must be above zero[3], so compare the export rate with the cost of heating water another way in that home.
Can a plumber install a solar diverter?
The plumber usually handles the cylinder, immersion and temperatures, while a competent electrician installs and notifies the diverter and wiring.
Does a diverter work with a combi boiler?
No. A diverter needs a hot water cylinder with an immersion heater to send surplus power to.
References
MCS (Microgeneration Certification Scheme) (2026). Record number of UK households combining renewables to improve energy resilience (20 August 2026) (opens in a new tab) ↑
Health and Safety Executive (2026). Legionnaires’ disease: hot and cold water systems (opens in a new tab) ↑
Ofgem (2026). Smart Export Guarantee (SEG) (opens in a new tab) ↑
Heating and Hotwater Industry Council (HHIC) (2026). HHIC and OFTEC urge Government to back hybrid heating systems to support off-grid households (opens in a new tab) ↑
GOV.UK (2026). Building regulations approval (opens in a new tab) ↑