Regulation compliance

Scotland's landlord safety rules: gas, CO and legionella

What the repairing standard asks of Scottish private landlords on gas, carbon monoxide, lead and legionella, and how plumbers can meet those requests.

Ava research teamPublished 7 min read

On this page
  1. What the repairing standard asks of a landlord
  2. Gas and carbon monoxide duties in practice
  3. Water: lead, legionella and private supplies
  4. A visit checklist that covers the guidance
  5. Example: one visit, three duties
  6. Wording for your reports and quotes
  7. Turning the rules into a landlord service
  8. Frequently asked questions
  9. References

Key takeaways

  • Scottish private lets must meet the repairing standard, which covers water, gas, electrical and heating installations[1].
  • The guidance expects an annual gas safety check, carbon monoxide detectors in every room with a fixed combustion appliance and a gas record to tenants within 28 days[2].
  • Landlords must assess legionella risk before the first let and review it at intervals of no more than two years[3].
  • Lead pipework from the boundary stopcock to the kitchen tap should not be present in a privately rented home[3], which creates real replacement work.

What the repairing standard asks of a landlord

In Scotland the legal floor for a private let is the repairing standard in the Housing (Scotland) Act 2006. It says installations for the supply of water, gas and electricity, and for space heating and heating water, must be in a reasonable state of repair and in proper working order[1]. The Act also tells everyone to have regard to Scottish Ministers' guidance on carbon monoxide detection, fire detection, the condition of pipes supplying drinking water and the installation of a fixed heating system[1].

That guidance is where the detail lives, and it is what letting agents and tribunal members read. The current statutory guidance applies from 1 March 2024[2]. If you work for landlords in Scotland, it is worth reading the gas and water annexes yourself, because the requests you get from agents are often second-hand summaries that miss part of the duty.

The market is small enough that reputation travels fast. Scotland had 3,260 plumbing, heating and air-conditioning business sites in 2026[4], so the firms that agents trust for compliance work are quickly known by name in each town.

Gas and carbon monoxide duties in practice

The gas duty matches the rest of Great Britain because it comes from the Gas Safety (Installation and Use) Regulations 1998. Each gas appliance and flue must be checked within 12 months of installation and at intervals of not more than 12 months[5]. The Scottish guidance repeats that every gas engineer doing this work must be on the Gas Safe Register, and that existing tenants get a copy of the record within 28 days of the check while new tenants get it before the tenancy starts[2].

Gas and CO duties for Scottish private lets, summarised from the repairing standard guidance, annex D2.
DutyWhat the guidance saysWhat you supply
Annual gas safety checkEach gas appliance and flue checked every yearCheck, record, advice on any defects
Gas safety recordCopy to existing tenants within 28 days; new tenants before they move inRecord issued the same day, in a format the agent can forward
Record keepingKeep at least two years, or until two further checksYour own archive by property address
Carbon monoxide detectionDetectors in all rooms with a fixed combustion appliance, plus any flue routeSurvey, supply and fit detectors, note expiry dates
Early checksA check up to two months early can keep the original due dateRota landlords on a fixed annual month

The carbon monoxide rule is wider than many landlords think. The guidance requires detectors in all rooms where there is a fixed combustion appliance, such as a boiler, fire, heater or stove, and it also covers rooms a flue passes through; cooking-only appliances are excluded[2]. Every carbon monoxide alarm fitted in the UK must meet EN 50291-1:2018, even though the rules on where alarms go differ between the four nations[6]. If you have also worked in England or Wales, do not carry their alarm rules north with you; see our note on rented homes in Wales for the contrast.

The guidance also mentions the 2018 flexibility for check timing: a check done up to two months before the due date can keep the original anniversary[2]. Use it to stop landlord portfolios drifting into one crowded month.

Water: lead, legionella and private supplies

The water annex is where Scotland goes further than most landlords expect. It says lead pipes should not be present in the drinking water supply of any privately rented property, and that lead pipes and tanks must be removed unless other owners withhold consent[3]. If a landlord is unsure whether lead is present, tenants must be told and a laboratory sample taken[3]. After replacement, the guidance expects the property to be sampled again to confirm the lead has gone[3].

Legionella is handled through a risk assessment. Landlords must assess hot and cold water systems before the property is first let, and review the assessment at intervals of no more than two years[3]. The guidance expects stored hot water at no less than 60°C and a flush of the system if one has not been done in the previous two years[3].

Share of Scotland's population on a private water supplyPrivate supplies in rented homes must be tested before a tenancy and every year after.
Share of Scotland's population on a private water supplyDonut chart. Private water supply: 4%.Private water supply: 4%4%
  • Private water supply 4%

Source: Scottish Government, 2024[3]

Show the data
ItemValue
Private water supply4%

Rural lets bring a third strand. Around 4% of Scotland's population is served by a private water supply[3], and the guidance expects those supplies to be tested before a tenancy begins and every year after, with the local authority doing the annual testing[3]. A landlord with a borehole or spring supply will need treatment kit kept in working order, which is maintenance work you can schedule alongside the gas check.

  • Ask whether the property is on a public or private supply before you quote.
  • Note pipe materials from the boundary stopcock to the kitchen tap on every visit.
  • Record hot water storage temperature and any dead legs you find.
  • Flag redundant pipework and uncovered cold water tanks in writing.

A visit checklist that covers the guidance

  1. Book with the right details

    Take the property address, tenant name and phone, access arrangements and the date of the last gas record. Ask whether the landlord wants carbon monoxide detection, legionella and lead checks priced on the same visit.

  2. Gas check and detectors

    Complete the appliance and flue checks, then walk every room with a fixed combustion appliance or flue route and test, replace or add detectors. Write each detector's expiry date on the record.

  3. Water walk-through

    Trace the supply from the boundary stopcock to the kitchen tap. Note any lead, any shared supply in a tenement and any private supply equipment.

  4. Hot and cold water observations

    Record cylinder temperature, flow at the shower and any outlets that are rarely used. These notes feed directly into the landlord's legionella assessment.

  5. Report the same day

    Send one report with three headings: gas, carbon monoxide, water. List defects, what you did, and what still needs a quote, so the agent can act without phoning you back.

Example: one visit, three duties

Example: a letting agent in Perth books an annual gas check for a 1930s ground-floor flat. On arrival the engineer finds a working combination boiler, no detector in the bedroom the flue passes through, and a short run of dull grey pipe under the kitchen sink. The gas check passes. The engineer fits a detector in the bedroom, records the expiry date, and photographs the suspected lead with a scratch test showing soft, bright metal.

The report goes to the agent that afternoon with a quote to replace the lead section, a note that the flat shares a supply with the flat above, and a reminder that the tenant should be told while the lead question is open. The agent gets one document that covers three separate parts of the guidance, which is exactly why they will ring the same firm next year.

Wording for your reports and quotes

Agents forward your words to landlords and sometimes to tribunals, so keep them factual and tied to what you saw. Avoid telling a landlord they are compliant overall; you can only speak for the installations you checked.

  • Gas: Appliances and flues listed above were checked on this date. Defects and actions are recorded on the gas safety record.
  • Carbon monoxide: Detectors were tested or fitted in the rooms named. Each detector's expiry date is shown.
  • Lead: Pipework that appears to be lead was seen between the stopcock and the kitchen tap. We recommend a laboratory sample and replacement.
  • Legionella: These observations are offered to support the landlord's own risk assessment. They are not a full assessment unless one was ordered.

Turning the rules into a landlord service

The Scottish guidance gives landlords several recurring tasks: the annual gas check, detector replacement as alarms expire, legionella reviews within two years and lead removal where it is still present. A simple yearly visit that covers gas, detectors and water observations, with lead replacement quoted separately, suits most small portfolios.

Most of the friction is in booking rather than the work itself: agents ring at busy times, tenants need notice, and access details get lost. If agent calls go unanswered while you are on a job, Ava can answer them, take the address, tenant contact and access notes, and book the routine visit into your diary.

Check before you quote: is the supply public or private, is the home in a shared tenement, and when was the last legionella review? Those three answers change the price and the paperwork.

Frequently asked questions

Do Scottish landlords need a gas safety check every year?

Yes. Each gas appliance and flue must be checked at intervals of not more than 12 months by a Gas Safe registered engineer, and tenants get a copy of the record.

Where must carbon monoxide detectors go in a Scottish rental?

The repairing standard guidance expects detectors in every room with a fixed combustion appliance, such as a boiler, fire or stove, and in rooms a flue passes through. Cooking-only appliances are excluded.

How often should a landlord's legionella assessment be reviewed in Scotland?

The guidance says at intervals of no more than two years, and the first assessment must be done before the property is first let.

Can a landlord keep lead pipes if the water tests fine?

The guidance says lead pipes should not be present in a privately rented home's drinking water supply and should be removed unless other owners withhold consent. A clear test does not change that expectation.

References

  1. legislation.gov.uk (The National Archives) (2006). Housing (Scotland) Act 2006, section 13: the repairing standard (opens in a new tab) ↑

  2. Scottish Government (2024). Repairing Standard: statutory guidance for private landlords, Annex D2: Gas (opens in a new tab) ↑

  3. Scottish Government (2024). Repairing Standard: statutory guidance for private landlords, Annex D1: Water (opens in a new tab) ↑

  4. Office for National Statistics (Nomis) (2026). UK Business Counts - local units by industry (SIC 2007 class 43.22), via Nomis (opens in a new tab) ↑

  5. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 36 (opens in a new tab) ↑

  6. Heating and Hotwater Industry Council (HHIC) (2025). A guide to carbon monoxide (CO) alarm legislation for heating engineers (opens in a new tab) ↑

Book a demo

See Ava handle your calls.

Book a short demo. We’ll walk through your calls and workflow, and agree what Ava should take care of.

Book a demo