Regulation compliance

Renting Homes (Wales): gas and safety duties for landlords

How the Welsh fitness for human habitation rules sit alongside gas safety law, and the checks landlords in Wales ask plumbers and heating engineers for.

Ava research teamPublished 7 min read

On this page
  1. Contract-holders, occupation contracts and why the words matter
  2. The three named duties and where you fit
  3. Gas: the 1998 regulations still do the heavy lifting
  4. Hazards in the 29 matters that plumbers can fix
  5. Decision guide: what to quote when an agent rings
  6. Example: a pre-letting visit in Swansea
  7. A timeline for a new occupation contract
  8. Paperwork that helps landlords prove fitness
  9. Frequently asked questions
  10. References

Key takeaways

  • Since 1 December 2022, landlords in Wales must keep homes fit for human habitation under the Renting Homes rules[1].
  • A carbon monoxide alarm is required in any room with a gas, oil or solid fuel burning appliance, and failing that duty means the home is treated as unfit[1].
  • The fitness rules do not replace the Gas Safety Regulations 1998, so the 12-monthly appliance and flue check still applies[1][2].
  • Private renting is about 12% of Welsh homes[3], a compact market where agents value one firm that covers gas, alarms and water hazards.

Contract-holders, occupation contracts and why the words matter

Wales changed its rental vocabulary when the Renting Homes (Wales) Act 2016 came into force. Tenants are now contract-holders, tenancies are occupation contracts, and the landlord has a duty to keep the dwelling fit for human habitation. Welsh Government guidance explains what landlords must do from 1 December 2022 to keep a property in good repair and fit to live in[1].

Using the same words as the agent on the phone saves time. When a Cardiff agent asks for a fitness visit before a new occupation contract starts, they usually mean a bundle: gas checks, alarms, and a look at hazards like damp or a failing water supply. Ask which items they want, because the bundle differs between agencies.

The market is modest in size. Wales had 1,900 plumbing, heating and air-conditioning business sites in 2026[4], and an estimated 184,900 privately rented homes at 31 March 2025[3]. Firms that understand the Welsh rules can build steady landlord work without competing on price alone.

Dwellings in Wales by tenure, 31 March 2025Owner-occupied and privately rented shares are provisional; figures sum to 99% due to rounding.
Dwellings in Wales by tenure, 31 March 2025Donut chart. Owner-occupied: 71%; Privately rented: 12%; Registered social landlords: 10%; Local authorities: 6%.Owner-occupied: 71%Privately rented: 12%Registered social landlords: 10%Local authorities: 6%1.49m homes
  • Owner-occupied 71%
  • Privately rented 12%
  • Registered social landlords 10%
  • Local authorities 6%

Source: Welsh Government, 2025[3]

Show the data
ItemValue
Owner-occupied71%
Privately rented12%
Registered social landlords10%
Local authorities6%

The three named duties and where you fit

The fitness regulations name three specific things a landlord must do. If any is missing, the dwelling is treated as if it were unfit for human habitation[1]. Two of them are squarely in the heating engineer's world, and the third often lands on your desk because the agent wants one contractor for the whole visit.

The three named fitness duties for landlords in Wales, from Welsh Government guidance.
Named dutyWhat the guidance requiresWho usually does it
Carbon monoxide alarmAn alarm in any room with a gas, oil or solid fuel burning appliance installedHeating engineer during the gas or oil service
Smoke alarmsOne on every storey, mains-connected and interlinkedElectrician, sometimes subcontracted by the plumbing firm
Electrical testingInspection at least every five years; report to the contract-holder within 14 days of the occupation dateRegistered electrician to BS 7671

The carbon monoxide duty is broader than gas. It applies to oil and solid fuel appliances too, which matters in rural Wales where oil boilers and wood burners are common. The guidance notes that carbon monoxide alarms are usually installed lower than smoke alarms and that their sensors usually need replacing more often, so check the expiry date on every visit[1]. Whatever the room, the alarm itself should meet EN 50291-1:2018, the standard that applies wherever alarms are fitted in the UK[5].

Gas: the 1998 regulations still do the heavy lifting

Welsh Government is explicit that the fitness rules do not replace a landlord's existing duties, including those under the Gas Safety (Installation and Use) Regulations 1998[1]. Those regulations require each gas appliance and flue in a let property to be checked within 12 months of installation and at intervals of not more than 12 months[2], and existing tenants must get the record within 28 days of the check[2].

The fitness guidance adds a hazard view on top. Uncombusted fuel gas is one of the 29 matters and circumstances, and the guidance recommends the installation is regularly tested so there are no leaks or other defects[1]. In plain terms: a valid gas record shows the landlord took the hazard seriously, and a lapsed one undermines any argument that the home was fit.

Rented homes in Wales still follow the Water Supply (Water Fittings) Regulations 1999 for water work, including the duty to notify the water company of certain installations before starting[6]. Our water fittings guide covers that side.

Hazards in the 29 matters that plumbers can fix

The guidance walks through 29 matters and circumstances that a court can weigh when deciding whether a home is fit[1]. Several are plumbing and heating problems that agents will ask you to put right before or during an occupation contract.

  • Damp and mould growth from leaking pipes, failed seals or overflowing cisterns.
  • Cold, where the heating system cannot keep the home warm or controls do not work.
  • Carbon monoxide and fuel combustion products from poorly maintained boilers, fires and flues.
  • Lead, from old supply pipes or lead-soldered joints on drinking water pipework.
  • Water supply, where flow, pressure or quality is inadequate for normal use.
  • Personal hygiene, sanitation and drainage, covering WCs, basins, baths and waste pipes.
  • Flames and hot surfaces, including exposed hot pipes and scalding hot water.

None of these has a single pass mark. Your job is to describe what you found and what you fixed, in words a landlord can show a court if the contract-holder disputes fitness.

Decision guide: what to quote when an agent rings

  1. Is there a gas, oil or solid fuel appliance? If yes, quote the service or safety check and a carbon monoxide alarm check for each room containing one.
  2. Is the gas record within 12 months? If not, the check comes first, before any other work in the visit.
  3. Has the agent asked for smoke alarms or electrical testing? If so, confirm whether your firm or a partner electrician will do it, and who issues the report.
  4. Are there known hazards in the listing notes, such as damp, a slow shower or an old lead supply? Price these as separate lines so the landlord can approve them individually.
  5. Is the occupation contract about to start? Agree the order of work so the reports reach the contract-holder on time.

Example: a pre-letting visit in Swansea

Example: an agent books a pre-letting visit for a two-storey terrace with a gas combination boiler and a wood burner in the front room. The engineer completes the gas safety check, tests the existing alarm by the boiler, and finds no carbon monoxide alarm in the front room. Because the wood burner is a solid fuel appliance, the room needs one, so the engineer fits a sealed-battery alarm low on the wall as the manufacturer instructs and records its expiry date.

Under the sink the engineer notices a weeping compression joint that has stained the cupboard base. It is fixed on the spot and photographed before and after. The report to the agent lists the gas record, the two alarms with expiry dates, the leak repair as a damp and mould risk removed, and a note that smoke alarms and electrical testing were outside this visit. The agent knows exactly what still needs booking.

A timeline for a new occupation contract

Agents usually ring when a property is between contract-holders, so the work has to fit into a short gap. A simple sequence keeps the gas and alarm items in the right order and stops reports arriving after the new contract-holder has moved in.

  1. Two to three weeks before the start date: agree the scope with the agent, including who does smoke alarms and electrical testing.
  2. One to two weeks before: carry out the gas safety check and fit or replace carbon monoxide alarms, so any remedial work has time to be done.
  3. Before keys are handed over: complete remedial plumbing, such as leaks or a failed shower valve, and send photographs.
  4. On or before the start date: send the gas record and alarm log to the agent so they can pass them on with the electrical report.

When the property is occupied, the same sequence works for annual visits. Book the gas check a month ahead of the due date, combine it with an alarm test and expiry check, and offer the landlord a single report each year. Landlords with several homes value a fixed annual month for each property, because it makes their own records easier to keep.

Paperwork that helps landlords prove fitness

Fitness disputes are decided on evidence, so the format of your paperwork matters almost as much as the work. Keep it short and specific.

  • Gas safety record with every appliance and flue listed, and defects classified.
  • Alarm log by room: alarm type, power source, test result and expiry date.
  • Photographs of any hazard found and of the finished repair.
  • A short note of anything you were not asked to check, so silence is not read as approval.

Agents in Wales often ring to book the gas check and alarms in the same call. Ava can answer while you are on a job, take the property, contract-holder contact and appliance details, and book the routine visit.

Frequently asked questions

Do landlords in Wales still need an annual gas safety check?

Yes. The Renting Homes fitness rules sit on top of the Gas Safety (Installation and Use) Regulations 1998, which require each appliance and flue in a let property to be checked every 12 months.

Which rooms need a carbon monoxide alarm in a Welsh rental?

Any room with a gas, oil or solid fuel burning appliance installed. If the alarm is missing, the dwelling is treated as unfit for human habitation.

Who can do the electrical inspection for a Welsh rental?

A qualified person such as a registered electrician working to BS 7671. The report must reach the contract-holder within 14 days of the occupation date.

Is a contract-holder the same as a tenant?

In everyday terms, yes. Since the Renting Homes (Wales) Act 2016 came into force, people renting a home in Wales are called contract-holders under an occupation contract.

References

  1. Welsh Government (2022). Fitness of homes for human habitation: guidance for landlords (opens in a new tab) ↑

  2. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 36 (opens in a new tab) ↑

  3. Welsh Government (2025). Dwelling stock estimates: as at 31 March 2025 (opens in a new tab) ↑

  4. Office for National Statistics (Nomis) (2026). UK Business Counts - local units by industry (SIC 2007 class 43.22), via Nomis (opens in a new tab) ↑

  5. Heating and Hotwater Industry Council (HHIC) (2025). A guide to carbon monoxide (CO) alarm legislation for heating engineers (opens in a new tab) ↑

  6. legislation.gov.uk (The National Archives) (1999). The Water Supply (Water Fittings) Regulations 1999, regulation 5 (opens in a new tab) ↑

Book a demo

See Ava handle your calls.

Book a short demo. We’ll walk through your calls and workflow, and agree what Ava should take care of.