Emergency out of hours

The Gas Industry Unsafe Situations Procedure explained

The Gas Industry Unsafe Situations Procedure explained: Immediately Dangerous, At Risk and Not to Current Standards, actions and words to use.

Ava research teamPublished 7 min read

On this page
  1. What the procedure is and why it exists
  2. The three categories at a glance
  3. Immediately Dangerous: act now, explain clearly
  4. At Risk: off until fixed
  5. Not to Current Standards: advise, do not alarm
  6. Paperwork that goes with each category
  7. Rented homes and landlord duties
  8. When you find someone else's warning notice
  9. Example: three findings on one visit
  10. Frequently asked questions
  11. References

Key takeaways

  • The procedure sorts what you find into Immediately Dangerous, At Risk and Not to Current Standards, each with its own action.
  • Making safe needs the responsible person's permission; if it is refused for an Immediately Dangerous situation, the gas emergency service is the next step.
  • Plain words matter: customers act on "this can kill" faster than on a category code.
  • Some unsafe situations must also be reported to HSE within 14 days when the cause lies in design, installation, modification or servicing[1].

What the procedure is and why it exists

The Gas Industry Unsafe Situations Procedure gives registered engineers a common way to classify and deal with unsafe gas installations and appliances. Before it, two engineers could find the same fault and do two different things. The procedure, now published by the Institution of Gas Engineers and Managers as IGEM/G/11, sets out the categories, the actions for each and the paperwork that goes with them.

It sits on top of the law rather than replacing it. No employer or self-employed person may carry out work on a gas fitting unless they belong to a class of persons approved by HSE, in practice the Gas Safe Register[2], and registered businesses are expected to follow the industry procedure when they find something unsafe. Engineers should always work from the current edition and their own training; this article is a practical overview, not a substitute for either.

The three categories at a glance

Overview of the categories; follow the current IGEM/G/11 edition for definitions and actions.
CategoryWhat it meansUsual actionWords for the customer
Immediately Dangerous (ID)A present danger to life or property if the appliance or installation stays connected or in useWith permission, turn off and disconnect, label, issue a warning notice"If this stays connected it could cause a fire, an explosion or carbon monoxide poisoning. I need to disconnect it now."
At Risk (AR)One or more faults that could become a danger in futureWith permission, turn off, label and issue a warning notice; treat as ID if turning off does not remove the risk"It's not dangerous this minute, but it could become so. It should stay off until it's repaired."
Not to Current Standards (NCS)Not unsafe, but would not meet the standards that apply to a new installation todayAdvise the customer, record it, and offer a quote to bring it up to standard"This is safe to use, but it was fitted to older standards. Here is what we'd change if you upgrade."

Immediately Dangerous: act now, explain clearly

An ID situation means the danger is present now. Typical examples include a gas escape, an appliance spilling combustion products into a room, or a flue that has come apart. The engineer's job is to remove the danger, which normally means turning the appliance off and disconnecting it from the gas supply, then attaching a warning label and completing a warning notice that the customer keeps.

You need permission from the responsible person, usually the owner or occupier. Most people agree as soon as they understand the risk, so the explanation matters more than the form. Talk about consequences, not codes. Then explain what happens next: who can repair it, whether you can quote today, and what they can use for heat or cooking in the meantime.

Script: "I've found that this fire is leaking gas at the connection. That's dangerous: it could ignite. With your permission I'm going to disconnect it and put a label on it so no one uses it by mistake. I'll give you a notice that explains what I found. It can be repaired, and I can give you a price for that before I leave."

If permission is refused for an ID situation, do not leave it as it is. Contact the gas emergency service, which can attend and make the installation safe. When told of a gas escape, the gas conveyor must attend as soon as reasonably practicable and stop the escape within 12 hours[3]. Record the refusal, the time of your call and the reference you are given.

At Risk: off until fixed

AR covers faults that are not dangerous right now but could become dangerous: for example, a flue terminal too close to an opening window, poor ventilation for an open-flued appliance, or a fault that would cause problems if conditions changed. With permission, turn the appliance off, label it and issue a warning notice explaining the fault and the risk.

The customer's agreement is again central. Some will want to keep using an AR appliance through a cold spell. Explain the risk honestly, offer interim options such as a loan heater, and record their decision on the notice and the job sheet. Where turning the appliance off does not remove the risk, the procedure treats the situation as ID.

Not to Current Standards: advise, do not alarm

NCS is the category most likely to be misused. It applies to installations that are safe but would not meet today's standards for a new fit, such as some older pipework routes or controls. Housing has changed a lot: only 2% of homes in England had a condensing combination boiler in 2001, against 63% in 2024[4], so engineers routinely work alongside installations fitted to very different rules.

Homes in England with a condensing combination boilerMany installations engineers meet were fitted to older standards
Homes in England with a condensing combination boilerColumn chart. 2001: 2%; 2024: 63%.0%20%40%60%80%2001: 2%2%20012024: 63%63%2024Homes in England with a condensing combination boilerColumn chart. 2001: 2%; 2024: 63%.0%20%40%60%80%2001: 2%2%20012024: 63%63%2024

Source: Ministry of Housing, Communities and Local Government (GOV.UK), 2024[4]

Show the data
ItemValue
20012%
202463%

Use NCS to inform, not to frighten or upsell. Write what does not meet current standards, explain it is not unsafe, and offer a quote for upgrading if the customer wants one. Never describe an NCS finding as dangerous to win a replacement job; that is the behaviour that gives honest engineers a bad name.

Paperwork that goes with each category

  • Warning notice: what was found, the category, the action taken, whether permission was given, and the customer's signature or a note that they declined to sign.
  • Warning label: attached to the appliance or installation for ID and AR, so anyone who visits later sees the warning.
  • Job sheet entry: the same facts, plus photos and readings, linked to the notice.
  • Copy for landlords: in rented homes, send the notice to the landlord or agent the same day as well as leaving it with the tenant.
  • RIDDOR check: a quick review of whether the cause brings the finding within the dangerous gas fittings duty.

The last point is easy to forget. Under RIDDOR, a registered business that has enough information to decide that a gas fitting is or was likely to cause death or serious harm because of its design, construction, installation, modification or servicing must report it to HSE within 14 days[1]. Many ID findings, and some AR ones, will meet that test; worn parts often will not.

Rented homes and landlord duties

Landlords must have a registered engineer carry out an annual gas safety check on each appliance and flue and give tenants the record before they move in or within 28 days[5]. An ID or AR finding on a tenant's appliance therefore lands with someone who has a legal duty to act. HSE's figures show 703 of the 2,010 dangerous gas fitting notifications in 2024/25 concerned rented premises[6].

Tell the tenant what you found and what they should not use, then send the landlord the notice with a clear request: who should repair it, and by when. Do not accept a landlord's instruction to reconnect an ID appliance without repair. Your registration, not theirs, is on the notice.

When you find someone else's warning notice

Engineers often arrive to find a label or notice left by another firm. Treat it as information, not a verdict. Check the installation yourself, classify what you find, and record it. If you agree, say so and carry on from there. If you disagree, perhaps because a fault has since been repaired or was misclassified, explain your findings in writing and avoid criticising the other engineer to the customer.

Never remove a label from an ID or AR appliance and put it back into use unless you have rectified the fault and tested it. If the customer has reconnected an appliance themselves after a disconnection, treat that as a fresh unsafe situation and explain why it matters.

Example: three findings on one visit

Example: an engineer called to a no-hot-water fault in a 1990s semi finds three things. The boiler's flue is sound but the boiler has a failed sensor: repaired and tested. A gas fire in the lounge spills combustion products on a spillage test: ID, disconnected with permission, labelled and noticed. The freestanding cooker has no stability bracket, so it could tip and strain its gas connection: AR, turned off with the owner's permission, labelled and noticed, and the engineer returns the next day to fit a bracket.

Example, continued: the engineer also notes that the gas pipe to the hob is run in a way that would not meet current standards for a new installation but is safe: NCS, explained and recorded. The office reviews the fire finding the next morning and decides it was caused by wear, not installation or servicing, so it is not reported under RIDDOR. The owner receives a quote for a replacement fire.

Frequently asked questions

What does Immediately Dangerous mean on a gas warning notice?

The appliance or installation is a present danger to life or property. The engineer will ask permission to disconnect it, label it and give you a warning notice.

Can I keep using an At Risk appliance?

The engineer will advise turning it off until it is repaired. It is not dangerous at that moment but could become so, and if turning it off does not remove the risk it is treated as Immediately Dangerous.

Is Not to Current Standards unsafe?

No. It means the installation would not meet today's standards for a new fit. It is safe to use, though you may choose to upgrade it.

What happens if I refuse to let an engineer disconnect a dangerous appliance?

For an Immediately Dangerous situation, the engineer can contact the gas emergency service, which can attend and make it safe.

References

  1. legislation.gov.uk (The National Archives) (2013). The Reporting of Injuries, Diseases and Dangerous Occurrences Regulations 2013, regulation 11 (opens in a new tab) ↑

  2. legislation.gov.uk (The National Archives) (1998). The Gas Safety (Installation and Use) Regulations 1998, regulation 3 (opens in a new tab) ↑

  3. legislation.gov.uk (The National Archives) (1996). The Gas Safety (Management) Regulations 1996, regulation 7 (opens in a new tab) ↑

  4. Ministry of Housing, Communities and Local Government (GOV.UK) (2024). English Housing Survey 2024 to 2025: Chapter 2, energy efficiency (opens in a new tab) ↑

  5. GOV.UK (2026). Your landlord's safety responsibilities (opens in a new tab) ↑

  6. Health and Safety Executive (2025). RIDGAS: Gas-related incidents reported in Great Britain (Tables 1 and 2) (opens in a new tab) ↑

Book a demo

See Ava handle your calls.

Book a short demo. We’ll walk through your calls and workflow, and agree what Ava should take care of.

Book a demo