Key takeaways
- Many unhappy customers never complain; an aftercare call finds problems while they are still small.
- Time calls to when problems show up: a few days after an install, after the first cold spell and again after a few weeks.
- Use a short script with open questions about heat, hot water, noise, pressure, controls and bills.
- Keep the call a service call: no sales pitch, and log every issue with an owner and a date.
Why customers stay quiet about problems
Most firms assume that if a customer has a problem after an install, they will ring. Many do not. In the government's consumer protection study, people who decided not to act on a consumer problem most often said it was not serious enough (22% of those cases) or that they meant to deal with it later (20%)[1]. Others thought complaining would be unsuccessful, found the process too complicated or did not know how to go about it[1].
For a heating firm, each of those silent customers is a risk. The radiator that never quite gets hot, the boiler that makes a new noise, the thermostat nobody understands: none of these feels worth a call on day three. By month three they have become 'the boiler they fitted has never been right', told to friends and written in a review. An aftercare call catches them while they are still a five-minute fix.
Aftercare calls also tell you things a satisfaction survey never will: which controls confuse people, which engineers explain the handover well, and which jobs quietly generate return visits. Treat them as part of quality control, not as a courtesy you drop when the diary is full.
When to call
| Job | First call | Second call | What usually shows up |
|---|---|---|---|
| Boiler replacement | Two to three days after | After the first cold spell or at four to six weeks | Pressure loss, noisy pump, controls confusion, cold radiators |
| Heat pump install | Within the first week | After the first sustained cold weather, then at around three months | Comfort complaints, controls and schedules, hot water timing, bills |
| Bathroom or shower install | One week after | One month after | Leaks under trays, sealant, pressure or temperature issues |
| System upgrade or power flush | One week after | Only if issues were raised | Cold spots returning, noise, pressure |
| Larger repair | Two or three days after | Not usually needed | Same fault returning, a new related fault |
The first call checks the basics while the engineer still remembers the job. The second is timed for when systems are tested by real use: a cold week for heating, a month of daily showers for a bathroom. If you only make one call, make the second one.
A short aftercare script
Keep the call under five minutes unless the customer wants to talk. Use open questions, and do not lead the customer towards 'everything's fine'.
Introduce and set the purpose
'Hi, it's Jo from Ashdown Heating. We fitted your new boiler last week and I'm just calling to check how it's been. Have you got two minutes?'
Ask about heat and hot water
'How have the heating and hot water been? Are all the rooms getting warm?'
Ask about anything unusual
'Have you noticed any new noises, drips or changes in the pressure on the front of the boiler?'
Ask about controls
'How are you getting on with the thermostat and the timer? Is there anything you'd like us to go through again?'
Ask the open question
'Is there anything at all about the job, or the way we did it, that you're not happy with?'
Close with a clear next step
Either 'Great, you know where we are' or 'I'll get an engineer to call you back today about that.'
The open question at the end matters most. Customers often say everything is fine and then, when asked directly, mention the one thing that has been bothering them.
Warning signs to listen for
- Pressure dropping or the customer topping up the system: possible leak, expansion vessel or relief valve issue.
- New noises: kettling, banging or a pump running loudly can point to air, sludge or flow problems.
- Some radiators cold or slow: balancing, air or valves not fully open.
- Error codes or the boiler locking out: note the code exactly.
- Controls confusion: the customer has given up on the programmer and leaves the heating on all the time.
- Hot water running cold too quickly: settings, sizing or a cylinder issue.
- Worries about bills, especially after a heat pump install, often linked to settings or expectations.
- Any mention of a smell, headaches or the alarm sounding: treat as urgent and follow your safety procedure.
Write down the customer's exact words. 'It makes a whooshing noise when the heating comes on in the morning' is far more useful to an engineer than 'customer reports noise'.
Heat pump customers need more aftercare
Heat pumps are becoming routine work for many firms. By the end of September 2026, 96,611 Boiler Upgrade Scheme installations had been paid out, including a record 3,332 in September alone[2]. Many of those customers had a gas or oil boiler for decades and have to learn a new way of heating: lower flow temperatures, longer running times and different controls.
96,611
Boiler Upgrade Scheme installations paid out by the end of September 2026[2]
That makes aftercare part of the product. Customers who are told during the first cold spell that steady running is normal, and shown how to set schedules, are far less likely to decide the system does not work. Plan at least three contacts for heat pump installs, and offer a visit if settings need adjusting.
Aftercare for older and vulnerable customers
Older customers and those with health conditions are often the least likely to ring with a small problem, and the most affected if heating is not working properly. They may worry about being a nuisance, or not want to admit they cannot work the new controls. For these customers, change the approach slightly.
- Call rather than text, and allow more time for the conversation.
- Offer to speak to a family member or carer as well, if the customer would like that.
- Ask specifically whether they are warm enough at night and first thing in the morning.
- Offer a short visit to go through the controls in person; a printed one-page guide stuck near the thermostat helps.
- Make an extra call after the first properly cold week of winter.
Keep it a service call
An aftercare call is part of the job you were paid for, not a sales opportunity. Resist adding 'while I've got you, have you thought about a service plan?' If the customer asks about other work, answer helpfully, but do not lead with it. The rules on unsolicited marketing calls, including the Telephone Preference Service, apply to calls made for marketing[3], and a call that turns into a pitch starts to look like one.
The record matters too. The digital Benchmark record has replaced the paper commissioning checklist and service record[4], so make sure the commissioning details are complete before you call. If the customer asks for their records, you can point them to where they are kept.
Act on what you hear
Log every issue
Against the job, with the customer's words, the date and who took the call.
Assign an owner and a date
Every issue gets a named person and a callback time, even if the answer is 'that's normal, here's why'.
Call back when you said you would
An aftercare call that raises an issue and then goes silent is worse than no call.
Feed back to the installer
Engineers should hear about issues from their own jobs, good and bad.
Review monthly
Count issues by type and installer; repeated themes point to training or process changes.
After the call, send a short message summarising anything agreed: 'Thanks for talking to us today. As discussed, Sam will call you tomorrow morning about the bedroom radiator.' It confirms you listened and gives the customer something to refer to if the callback does not happen.
Over time, aftercare notes become one of the most useful sources of training material you have. If three customers in a month struggle with the same smart thermostat, add a ten-minute controls handover to every install. If one installer's jobs keep producing pressure-loss calls, look at their filling and venting routine. The calls pay for themselves through the problems they prevent on future jobs.
Example: the radiator nobody mentioned
Example: a fictional firm fits a combi in early October. The three-day call goes well. At the five-week call, after the first frosty week, the customer says everything is fine. Asked the open question, she mentions that the back bedroom radiator 'takes forever' and her son has been using a fan heater. The office books a 30-minute visit; the engineer finds a lockshield valve barely open after the system was refilled, balances the system and shows the customer the controls again. In this example a small fix stops a complaint, and the customer later recommends the firm to a neighbour.
Frequently asked questions
Who should make aftercare calls, the engineer or the office?
The office usually, so calls happen consistently and issues are logged. The installing engineer should hear the results and handle any technical callbacks.
Is an aftercare call marketing?
Not if it is genuinely about the work you did. Keep it to checking the installation and resolving issues; avoid turning it into a sales pitch.
What if the customer does not answer?
Try once more at a different time, then send a short text or email asking them to call if anything is not right. Log the attempts.
References
Department for Business, Energy and Industrial Strategy (GOV.UK) (2022). Consumer protection study 2022 (Figure 21, reasons for not acting) (opens in a new tab) ↑
Department for Energy Security and Net Zero (2026). Boiler Upgrade Scheme (BUS) monthly statistics: England and Wales, September 2026 (opens in a new tab) ↑
legislation.gov.uk (The National Archives) (2003). The Privacy and Electronic Communications (EC Directive) Regulations 2003, regulation 21 (opens in a new tab) ↑
Heating and Hotwater Industry Council (HHIC) (2026). Benchmark goes digital - what homeowners need to know (opens in a new tab) ↑